Search Results (12 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-48978 1 Ui 1 Edgeswitch 2025-08-23 7.5 High
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network. Affected Products: EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) Mitigation: Update the EdgeMAX EdgeSwitch to Version 1.11.1 or later.
CVE-2025-27211 1 Ui 1 Edgeswitch 2025-08-05 7.5 High
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.
CVE-2020-8233 2 Opensuse, Ui 14 Backports Sle, Leap, Edgeswitch Firmware and 11 more 2024-11-21 8.8 High
A command injection vulnerability exists in EdgeSwitch firmware <v1.9.0 that allowed an authenticated read-only user to execute arbitrary shell commands over the HTTP interface, allowing them to escalate privileges.
CVE-2020-8232 1 Ui 12 Edgeswitch Firmware, Ep-16-xg, Ep-s16 and 9 more 2024-11-21 6.5 Medium
An information disclosure vulnerability exists in EdgeMax EdgeSwitch firmware v1.9.0 that allowed read only users could obtain unauthorized information through SNMP community pages.
CVE-2020-8126 1 Ui 1 Edgeswitch 2024-11-21 7.8 High
A privilege escalation in the EdgeSwitch prior to version 1.7.1, an CGI script don't fully sanitize the user input resulting in local commands execution, allowing an operator user (Privilege-1) to escalate privileges and became administrator (Privilege-15).
CVE-2019-5446 1 Ui 12 Edgeswitch Firmware, Ep-s16., Es-12f and 9 more 2024-11-21 7.2 High
Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root.
CVE-2019-5445 1 Ui 12 Edgeswitch Firmware, Ep-s16., Es-12f and 9 more 2024-11-21 4.9 Medium
DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands.
CVE-2019-5426 1 Ui 1 Edgeswitch X 2024-11-21 4.8 Medium
In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, an unauthenticated user can use the "local port forwarding" and "dynamic port forwarding" (SOCKS proxy) functionalities. Remote attackers without credentials can exploit this bug to access local services or forward traffic through the device if SSH is enabled in the system settings.
CVE-2019-5425 1 Ui 1 Edgeswitch X 2024-11-21 N/A
In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, an authenticated user can execute arbitrary shell commands over the SSH interface bypassing the CLI interface, which allow them to escalate privileges to root.
CVE-2019-5424 1 Ui 1 Edgeswitch X 2024-11-21 8.8 High
In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, a privileged user can execute arbitrary shell commands over the SSH CLI interface. This allows to execute shell commands under the root user.
CVE-2018-12590 1 Ui 2 Edgeswitch, Edgeswitch Firmware 2024-11-21 7.2 High
Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an externally controlled format-string vulnerability due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admin account could escape the restricted CLI and execute arbitrary code.
CVE-2015-9266 2 Ubnt, Ui 23 Airos 4 Xs2, Airos 4 Xs5, Edgeswitch Xp Firmware and 20 more 2024-11-21 N/A
The web management interface of Ubiquiti airMAX, airFiber, airGateway and EdgeSwitch XP (formerly TOUGHSwitch) allows an unauthenticated attacker to upload and write arbitrary files using directory traversal techniques. An attacker can exploit this vulnerability to gain root privileges. This vulnerability is fixed in the following product versions (fixes released in July 2015, all prior versions are affected): airMAX AC 7.1.3; airMAX M (and airRouter) 5.6.2 XM/XW/TI, 5.5.11 XM/TI, and 5.5.10u2 XW; airGateway 1.1.5; airFiber AF24/AF24HD 2.2.1, AF5x 3.0.2.1, and AF5 2.2.1; airOS 4 XS2/XS5 4.0.4; and EdgeSwitch XP (formerly TOUGHSwitch) 1.3.2.