Filtered by vendor Advantech
Subscriptions
Filtered by product Eki-6333ac-1gpo Firmware
Subscriptions
Total
15 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-50367 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 7.2 High |
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "sta_log_htm" API which are not properly sanitized before being concatenated to OS level commands. | ||||
CVE-2024-50362 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 7.2 High |
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "connection_profile_apply" API which are not properly sanitized before being concatenated to OS level commands. | ||||
CVE-2024-50361 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 7.2 High |
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "certificate_file_remove" API which are not properly sanitized before being concatenated to OS level commands. | ||||
CVE-2024-50363 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 7.2 High |
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "mp_apply" API which are not properly sanitized before being concatenated to OS level commands. | ||||
CVE-2024-50364 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 7.2 High |
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "export_log" API which are not properly sanitized before being concatenated to OS level commands. | ||||
CVE-2024-50365 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 7.2 High |
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "lan_apply" API which are not properly sanitized before being concatenated to OS level commands. | ||||
CVE-2024-50359 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 7.2 High |
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "scan_ap" API which are not properly sanitized before being concatenated to OS level commands. | ||||
CVE-2024-50360 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 7.2 High |
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "snmp_apply" API which are not properly sanitized before being concatenated to OS level commands. | ||||
CVE-2024-50366 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 7.2 High |
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "applications_apply" API which are not properly sanitized before being concatenated to OS level commands. | ||||
CVE-2024-50371 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 9.8 Critical |
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation. | ||||
CVE-2024-50372 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 9.8 Critical |
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation. | ||||
CVE-2024-50373 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 9.8 Critical |
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation. | ||||
CVE-2024-50374 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 9.8 Critical |
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation. | ||||
CVE-2024-50375 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 9.8 Critical |
A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point. | ||||
CVE-2024-50377 | 1 Advantech | 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware | 2024-11-26 | 6.5 Medium |
A CWE-798 "Use of Hard-coded Credentials" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password. |
Page 1 of 1.