Filtered by vendor Tenda Subscriptions
Filtered by product F1203 Subscriptions
Total 28 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-38931 1 Tenda 16 Ac10, Ac10 Firmware, Ac1206 and 13 more 2024-10-17 9.8 Critical
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.
CVE-2023-38933 1 Tenda 18 Ac10, Ac10 Firmware, Ac1206 and 15 more 2024-10-17 9.8 Critical
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
CVE-2023-38934 1 Tenda 6 F1203, F1203 Firmware, Fh1203 and 3 more 2024-10-15 9.8 Critical
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
CVE-2023-38936 1 Tenda 18 Ac10, Ac10 Firmware, Ac1206 and 15 more 2024-10-15 9.8 Critical
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
CVE-2023-38930 1 Tenda 10 Ac5, Ac5 Firmware, Ac7 and 7 more 2024-10-15 9.8 Critical
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
CVE-2023-38940 1 Tenda 6 F1203, F1203 Firmware, Fh1203 and 3 more 2024-10-11 9.8 Critical
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2022-46538 1 Tenda 2 F1203, F1203 Firmware 2024-08-03 9.8 Critical
Tenda F1203 V2.0.1.6 was discovered to contain a command injection vulnerability via the mac parameter at /goform/WriteFacMac.
CVE-2022-46534 1 Tenda 2 F1203, F1203 Firmware 2024-08-03 7.5 High
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the speed_dir parameter at /goform/SetSpeedWan.
CVE-2022-46536 1 Tenda 2 F1203, F1203 Firmware 2024-08-03 7.5 High
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the limitSpeedUp parameter at /goform/SetClientState.
CVE-2022-46549 1 Tenda 2 F1203, F1203 Firmware 2024-08-03 7.5 High
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/saveParentControlInfo.
CVE-2022-46550 1 Tenda 2 F1203, F1203 Firmware 2024-08-03 7.5 High
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the urls parameter at /goform/saveParentControlInfo.
CVE-2022-46542 1 Tenda 2 F1203, F1203 Firmware 2024-08-03 7.5 High
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/addressNat.
CVE-2022-46547 1 Tenda 2 F1203, F1203 Firmware 2024-08-03 7.5 High
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/VirtualSer.
CVE-2022-46530 1 Tenda 2 F1203, F1203 Firmware 2024-08-03 7.5 High
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the mac parameter at /goform/GetParentControlInfo.
CVE-2022-46543 1 Tenda 2 F1203, F1203 Firmware 2024-08-03 7.5 High
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the mitInterface parameter at /goform/addressNat.
CVE-2022-46548 1 Tenda 2 F1203, F1203 Firmware 2024-08-03 7.5 High
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/DhcpListClient.
CVE-2022-46551 1 Tenda 2 F1203, F1203 Firmware 2024-08-03 7.5 High
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the time parameter at /goform/saveParentControlInfo.
CVE-2022-46541 1 Tenda 2 F1203, F1203 Firmware 2024-08-03 7.5 High
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the ssid parameter at /goform/fast_setting_wifi_set.
CVE-2022-46546 1 Tenda 2 F1203, F1203 Firmware 2024-08-03 7.5 High
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the entrys parameter at /goform/RouteStatic.
CVE-2022-46545 1 Tenda 2 F1203, F1203 Firmware 2024-08-03 7.5 High
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/NatStaticSetting.