Filtered by vendor Tenda
Subscriptions
Filtered by product Fh1206 Firmware
Subscriptions
Total
26 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-34943 | 1 Tenda | 1 Fh1206 Firmware | 2024-11-21 | 9.8 Critical |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/NatStaticSetting. | ||||
CVE-2024-34942 | 1 Tenda | 1 Fh1206 Firmware | 2024-11-21 | 8.8 High |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/exeCommand. | ||||
CVE-2024-33214 | 1 Tenda | 1 Fh1206 Firmware | 2024-11-21 | 7.5 High |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter in ip/goform/RouteStatic. | ||||
CVE-2024-42986 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-10-24 | 7.5 High |
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the PPPOEPassword parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | ||||
CVE-2024-42977 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-10-24 | 7.5 High |
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the qos parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | ||||
CVE-2024-42987 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-09-03 | 7.5 High |
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the modino parameter in the fromPptpUserAdd function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | ||||
CVE-2024-42978 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-09-03 | 9.8 Critical |
An issue in the handler function in /goform/telnet of Tenda FH1206 v02.03.01.35 allows attackers to execute arbitrary commands via a crafted HTTP request. | ||||
CVE-2024-44390 | 2 Tencacn, Tenda | 3 Fh1206, Fh1206 Firmware, Fh1206 Firmware | 2024-08-27 | 8 High |
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset. | ||||
CVE-2024-44387 | 2 Tencacn, Tenda | 3 Fh1206, Fh1206 Firmware, Fh1206 Firmware | 2024-08-27 | 6.5 Medium |
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the functino formWrlExtraGet. | ||||
CVE-2024-44386 | 1 Tenda | 1 Fh1206 Firmware | 2024-08-23 | 7.3 High |
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function fromSetIpBind. | ||||
CVE-2024-7707 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-08-22 | 8.8 High |
A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-7614 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-08-21 | 8.8 High |
A vulnerability was found in Tenda FH1206 1.2.0.8(8155). It has been classified as critical. Affected is the function fromqossetting of the file /goform/qossetting. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-7615 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-08-21 | 8.8 High |
A vulnerability was found in Tenda FH1206 1.2.0.8. It has been declared as critical. Affected by this vulnerability is the function fromSafeClientFilter/fromSafeMacFilter/fromSafeUrlFilter. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-7613 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-08-21 | 8.8 High |
A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-42981 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-08-16 | 7.5 High |
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the delno parameter in the fromPptpUserSetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | ||||
CVE-2024-42980 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-08-16 | 7.5 High |
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ImForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | ||||
CVE-2024-42969 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-08-16 | 7.5 High |
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | ||||
CVE-2024-42968 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-08-16 | 6.5 Medium |
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the Go parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | ||||
CVE-2024-42973 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-08-16 | 6.5 Medium |
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSetlpBind function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | ||||
CVE-2024-42974 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-08-16 | 6.5 Medium |
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromwebExcptypemanFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. |