Filtered by vendor Sick
Subscriptions
Filtered by product Ftmg-esd15axx Firmware
Subscriptions
Total
8 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-31409 | 1 Sick | 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more | 2024-11-21 | 5.3 Medium |
Uncontrolled Resource Consumption in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an remote attacker to influence the availability of the webserver by invocing a Slowloris style attack via HTTP requests. | ||||
CVE-2023-31408 | 1 Sick | 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more | 2024-11-21 | 5.3 Medium |
Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker to potentially steal user credentials that are stored in the user’s browsers local storage via cross-site-scripting attacks. | ||||
CVE-2023-23450 | 1 Sick | 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more | 2024-11-21 | 6.2 Medium |
Use of Password Hash Instead of Password for Authentication in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to use a password hash instead of an actual password to login to a valid user account via the REST interface. | ||||
CVE-2023-23449 | 1 Sick | 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more | 2024-11-21 | 5.3 Medium |
Observable Response Discrepancy in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker to gain information about valid usernames by analyzing challenge responses from the server via the REST interface. | ||||
CVE-2023-23448 | 1 Sick | 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more | 2024-11-21 | 5.3 Medium |
Inclusion of Sensitive Information in Source Code in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker to gain information about valid usernames via analysis of source code. | ||||
CVE-2023-23447 | 1 Sick | 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more | 2024-11-21 | 7.5 High |
Uncontrolled Resource Consumption in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to influence the availability of the webserver by invocing several open file requests via the REST interface. | ||||
CVE-2023-23446 | 1 Sick | 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more | 2024-11-21 | 7.5 High |
Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to download files by using a therefore unpriviledged account via the REST interface. | ||||
CVE-2023-23445 | 1 Sick | 14 Ftmg-esd15axx, Ftmg-esd15axx Firmware, Ftmg-esd20axx and 11 more | 2024-11-21 | 7.5 High |
Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to gain unauthorized access to data fields by using a therefore unpriviledged account via the REST interface. |
Page 1 of 1.