Search vulnerabilities

Results 5

CVE-2019-25717

Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration details from the exposed log files.

CVSS 4.0 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2019-25716

Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.

CVSS 4.0 · 7.1 High EPSS < 1% KEV · Not listed
Vendors
CVE-2018-19014

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Log files are accessible over an unauthenticated network connection. By accessing the log files, an attacker is able to gain insights about internals of the patient monitor, the location of the monitor, and wired network configuration.

CVSS 3.0 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2018-19012

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Via a specific dialog it is possible to break out of the kiosk mode and reach the underlying operating system. By breaking out of the kiosk mode, an attacker is able to take control of the operating system.

CVSS 3.0 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2018-19010

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. A malformed network packet may cause the monitor to reboot. By repeatedly sending the malformed network packet, an attacker may be able to disrupt patient monitoring by causing the monitor to repeatedly reboot until it falls back to default configuration and loses network connectivity.

CVSS 3.0 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors