Filtered by vendor Siemens Subscriptions
Filtered by product Opcenter Execution Process Subscriptions
Total 3 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2020-7588 1 Siemens 13 Opcenter Execution Discrete, Opcenter Execution Foundation, Opcenter Execution Process and 10 more 2024-11-21 5.3 Medium
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself.
CVE-2020-7587 1 Siemens 13 Opcenter Execution Discrete, Opcenter Execution Foundation, Opcenter Execution Process and 10 more 2024-11-21 8.2 High
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
CVE-2020-7581 1 Siemens 11 Opcenter Execution Discrete, Opcenter Execution Foundation, Opcenter Execution Process and 8 more 2024-11-21 6.7 Medium
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.