Filtered by vendor Siemens Subscriptions
Filtered by product Sentron Pac2200 Clp Subscriptions
Total 1 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2020-17437 4 Contiki-os, Open-iscsi Project, Siemens and 1 more 21 Contiki, Open-iscsi, Sentron 3va Com100 and 18 more 2024-08-04 8.2 High
An issue was discovered in uIP 1.0, as used in Contiki 3.0 and other products. When the Urgent flag is set in a TCP packet, and the stack is configured to ignore the urgent data, the stack attempts to use the value of the Urgent pointer bytes to separate the Urgent data from the normal data, by calculating the offset at which the normal data should be present in the global buffer. However, the length of this offset is not checked; therefore, for large values of the Urgent pointer bytes, the data pointer can point to memory that is way beyond the data buffer in uip_process in uip.c.