Filtered by vendor Siemens
Subscriptions
Filtered by product Simatic Hmi Basic Panels 2nd Generation
Subscriptions
Total
3 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2021-3449 | 13 Checkpoint, Debian, Fedoraproject and 10 more | 172 Multi-domain Management, Multi-domain Management Firmware, Quantum Security Gateway and 169 more | 2024-11-21 | 5.9 Medium |
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j). | ||||
CVE-2020-7592 | 1 Siemens | 9 Simatic Hmi Basic Panels 1st Generation, Simatic Hmi Basic Panels 2nd Generation, Simatic Hmi Comfort Panels and 6 more | 2024-11-21 | 6.5 Medium |
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information. | ||||
CVE-2020-15786 | 1 Siemens | 8 Simatic Hmi Basic Panels 2nd Generation, Simatic Hmi Basic Panels 2nd Generation Firmware, Simatic Hmi Comfort Panels and 5 more | 2024-11-21 | 9.8 Critical |
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack. |
Page 1 of 1.