Filtered by vendor Seiko-sol Subscriptions
Filtered by product Skybridge Mb-a200 Subscriptions
Total 6 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2022-36560 1 Seiko-sol 2 Skybridge Mb-a200, Skybridge Mb-a200 Firmware 2024-08-03 9.8 Critical
Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain multiple hard-coded passcodes for root. Attackers are able to access the passcodes at /etc/srapi/config/system.conf and /usr/sbin/ssol-sshd.sh.
CVE-2022-36559 1 Seiko-sol 2 Skybridge Mb-a200, Skybridge Mb-a200 Firmware 2024-08-03 9.8 Critical
Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain a command injection vulnerability via the Ping parameter at ping_exec.cgi.
CVE-2023-25184 1 Seiko-sol 6 Skybridge Basic Mb-a130, Skybridge Basic Mb-a130 Firmware, Skybridge Mb-a200 and 3 more 2024-08-02 7.5 High
Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier.
CVE-2023-23901 1 Seiko-sol 4 Skybridge Basic Mb-a130, Skybridge Basic Mb-a130 Firmware, Skybridge Mb-a200 and 1 more 2024-08-02 6.5 Medium
Improper following of a certificate's chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product.
CVE-2023-23578 1 Seiko-sol 2 Skybridge Mb-a200, Skybridge Mb-a200 Firmware 2024-08-02 7.5 High
Improper access control vulnerability in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier allows a remote unauthenticated attacker to connect to the product's ADB port.
CVE-2023-22441 1 Seiko-sol 4 Skybridge Basic Mb-a130, Skybridge Basic Mb-a130 Firmware, Skybridge Mb-a200 and 1 more 2024-08-02 8.6 High
Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier