Filtered by vendor Siemens Subscriptions
Filtered by product Totally Integrated Automation Portal Subscriptions
Total 10 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2024-33698 1 Siemens 4 Simatic Information Server, Simatic Pcs Neo, Sinec Nms and 1 more 2024-09-10 9.8 Critical
A vulnerability has been identified in SIMATIC Information Server 2022 (All versions), SIMATIC Information Server 2024 (All versions), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.
CVE-2023-46285 1 Siemens 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more 2024-09-10 7.5 High
A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.
CVE-2023-46284 1 Siemens 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more 2024-09-10 7.5 High
A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
CVE-2023-46283 1 Siemens 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more 2024-09-10 7.5 High
A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
CVE-2023-46282 1 Siemens 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more 2024-09-10 7.1 High
A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.
CVE-2023-46281 1 Siemens 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more 2024-09-10 7.1 High
A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.
CVE-2019-10934 1 Siemens 1 Totally Integrated Automation Portal 2024-08-04 7.8 High
A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions < V16 Update 6), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2020-25238 1 Siemens 2 Simatic Process Control System Neo, Totally Integrated Automation Portal 2024-08-04 7.8 High
A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.
CVE-2022-27194 1 Siemens 3 Simatic Pcs Neo, Sinetplan, Totally Integrated Automation Portal 2024-08-03 7.5 High
A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions < V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually.
CVE-2023-30757 1 Siemens 1 Totally Integrated Automation Portal 2024-08-02 6.2 Medium
A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). The know-how protection feature in affected products does not properly update the encryption of existing program blocks when a project file is updated. This could allow attackers with access to the project file to recover previous - yet unprotected - versions of the project without the knowledge of the know-how protection password.