Filtered by vendor Tenda Subscriptions
Filtered by product W9 Firmware Subscriptions
Total 13 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2024-0538 1 Tenda 2 W9, W9 Firmware 2024-10-23 8.8 High
A vulnerability has been found in Tenda W9 1.0.0.7(4456) and classified as critical. This vulnerability affects the function formQosManage_auto of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250708. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0537 1 Tenda 2 W9, W9 Firmware 2024-08-27 8.8 High
A vulnerability, which was classified as critical, was found in Tenda W9 1.0.0.7(4456). This affects the function setWrlBasicInfo of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250707. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-51102 1 Tenda 2 W9, W9 Firmware 2024-08-02 9.8 Critical
Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a stack overflow via the function formWifiMacFilterSet.
CVE-2023-51100 1 Tenda 2 W9, W9 Firmware 2024-08-02 9.8 Critical
Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a command injection vulnerability via the function formGetDiagnoseInfo .
CVE-2023-51098 1 Tenda 2 W9, W9 Firmware 2024-08-02 9.8 Critical
Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a command injection vulnerability via the function formSetDiagnoseInfo .
CVE-2023-51099 1 Tenda 2 W9, W9 Firmware 2024-08-02 9.8 Critical
Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a command injection vulnerability via the function formexeCommand .
CVE-2023-51097 1 Tenda 2 W9, W9 Firmware 2024-08-02 9.8 Critical
Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a stack overflow via the function formSetAutoPing.
CVE-2023-51101 1 Tenda 2 W9, W9 Firmware 2024-08-02 9.8 Critical
Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a stack overflow via the function formSetUplinkInfo.
CVE-2024-0541 1 Tenda 2 W9, W9 Firmware 2024-08-01 8.8 High
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. Affected by this vulnerability is the function formAddSysLogRule of the component httpd. The manipulation of the argument sysRulenEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250711. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0536 1 Tenda 2 W9, W9 Firmware 2024-08-01 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda W9 1.0.0.7(4456). Affected by this issue is the function setWrlAccessList of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-250706 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0540 1 Tenda 2 W9, W9 Firmware 2024-08-01 6.3 Medium
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. Affected is the function formOfflineSet of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-250710 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0539 1 Tenda 2 W9, W9 Firmware 2024-08-01 8.8 High
A vulnerability was found in Tenda W9 1.0.0.7(4456) and classified as critical. This issue affects the function formQosManage_user of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250709 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0542 1 Tenda 2 W9, W9 Firmware 2024-08-01 8.8 High
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. Affected by this issue is the function formWifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250712. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.