CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2021-33004 | 1 Advantech | 1 Webaccess\/hmi Designer | 2024-11-21 | 7.8 High |
The affected product is vulnerable to memory corruption condition due to lack of proper validation of user supplied files, which may allow an attacker to execute arbitrary code. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior). | ||||
CVE-2021-33002 | 1 Advantech | 1 Webaccess\/hmi Designer | 2024-11-21 | 7.8 High |
Opening a maliciously crafted project file may cause an out-of-bounds write, which may allow an attacker to execute arbitrary code. User interaction is require on the WebAccess HMI Designer (versions 2.1.9.95 and prior). | ||||
CVE-2021-33000 | 1 Advantech | 1 Webaccess\/hmi Designer | 2024-11-21 | 7.8 High |
Parsing a maliciously crafted project file may cause a heap-based buffer overflow, which may allow an attacker to perform arbitrary code execution. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior). | ||||
CVE-2020-16229 | 1 Advantech | 1 Webaccess\/hmi Designer | 2024-11-21 | 7.8 High |
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause a type confusion condition, which may allow remote code execution, disclosure/modification of information, or cause the application to crash. | ||||
CVE-2020-16217 | 1 Advantech | 1 Webaccess\/hmi Designer | 2024-11-21 | 7.8 High |
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. A double free vulnerability caused by processing specially crafted project files may allow remote code execution, disclosure/modification of information, or cause the application to crash. | ||||
CVE-2020-16215 | 1 Advantech | 1 Webaccess\/hmi Designer | 2024-11-21 | 7.8 High |
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause a stack-based buffer overflow, which may allow remote code execution, disclosure/modification of information, or cause the application to crash. | ||||
CVE-2020-16213 | 1 Advantech | 1 Webaccess\/hmi Designer | 2024-11-21 | 7.8 High |
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause the system to write outside the intended buffer area, which may allow remote code execution, disclosure/modification of information, or cause the application to crash. | ||||
CVE-2020-16211 | 1 Advantech | 1 Webaccess\/hmi Designer | 2024-11-21 | 5.5 Medium |
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. An out-of-bounds read vulnerability may be exploited by processing specially crafted project files, which may allow an attacker to read information. | ||||
CVE-2020-16207 | 1 Advantech | 1 Webaccess\/hmi Designer | 2024-11-21 | 7.8 High |
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by opening specially crafted project files that may overflow the heap, which may allow remote code execution, disclosure/modification of information, or cause the application to crash. | ||||
CVE-2019-16901 | 1 Advantech | 1 Webaccess\/hmi Designer | 2024-11-21 | 7.5 High |
Advantech WebAccess/HMI Designer 2.1.9.31 has Exception Handler Chain corruption starting at Unknown Symbol @ 0x0000000000000000 called from ntdll!RtlRaiseStatus+0x00000000000000b4. | ||||
CVE-2019-16900 | 1 Advantech | 1 Webaccess\/hmi Designer | 2024-11-21 | 7.5 High |
Advantech WebAccess/HMI Designer 2.1.9.31 has a User Mode Write AV starting at MSVCR90!memcpy+0x000000000000015c. | ||||
CVE-2019-16899 | 1 Advantech | 1 Webaccess\/hmi Designer | 2024-11-21 | 7.5 High |
In Advantech WebAccess/HMI Designer 2.1.9.31, Data from a Faulting Address controls Code Flow starting at PM_V3!CTagInfoThreadBase::GetNICInfo+0x0000000000512918. |