Filtered by vendor Primx Subscriptions
Filtered by product Zonecentral Subscriptions
Total 7 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-50444 1 Primx 3 Zed\!, Zedmail, Zonecentral 2024-11-21 7.5 High
By default, .ZED containers produced by PRIMX ZED! for Windows before Q.2020.3 (ANSSI qualification submission); ZED! for Windows before Q.2021.2 (ANSSI qualification submission); ZONECENTRAL for Windows before Q.2021.2 (ANSSI qualification submission); ZONECENTRAL for Windows before 2023.5; ZEDMAIL for Windows before 2023.5; and ZED! for Windows, Mac, Linux before 2023.5 include an encrypted version of sensitive user information, which could allow an unauthenticated attacker to obtain it via brute force.
CVE-2023-50442 1 Primx 1 Zonecentral 2024-11-21 5.5 Medium
Encrypted folders created by PRIMX ZONECENTRAL through 2023.5 can be modified by a local attacker (with appropriate privileges) so that specific file types are excluded from encryption temporarily. (This modification can, however, be detected, as described in the Administrator Guide.)
CVE-2023-50441 1 Primx 1 Zonecentral 2024-11-21 5.5 Medium
Encrypted folders created by PRIMX ZONECENTRAL for Windows before Q.2021.2 (ANSSI qualification submission) or ZONECENTRAL for Windows before 2023.5 can be modified by an unauthenticated attacker to include a UNC reference so that it could trigger outbound network traffic from computers on which folders are opened.
CVE-2023-50440 1 Primx 3 Zed\!, Zedmail, Zonecentral 2024-11-21 5.5 Medium
ZED containers produced by PRIMX ZED! for Windows before Q.2020.3 (ANSSI qualification submission); ZED! for Windows before Q.2021.2 (ANSSI qualification submission); ZONECENTRAL for Windows before Q.2021.2 (ANSSI qualification submission); ZONECENTRAL for Windows before 2023.5; ZEDMAIL for Windows before 2023.5; ZED! for Windows, Mac, Linux before 2023.5; ZEDFREE for Windows, Mac, Linux before 2023.5; or ZEDPRO for Windows, Mac, Linux before 2023.5 can be modified by an unauthenticated attacker to include a UNC reference so that it could trigger network access to an attacker-controlled computer when opened by the victim.
CVE-2023-50439 1 Primx 3 Zed\!, Zedmail, Zonecentral 2024-11-21 5.3 Medium
ZED containers produced by PRIMX ZED! for Windows before Q.2020.3 (ANSSI qualification submission), ZED! for Windows before Q.2021.2 (ANSSI qualification submission), ZONECENTRAL for Windows before Q.2021.2 (ANSSI qualification submission), ZONECENTRAL for Windows before 2023.5, or ZEDMAIL for Windows before 2023.5 disclose the original path in which the containers were created, which allows an unauthenticated attacker to obtain some information regarding the context of use (project name, etc.).
CVE-2019-7312 1 Primx 3 Zed, Zedmail, Zonecentral 2024-11-21 N/A
Limited plaintext disclosure exists in PRIMX Zed Entreprise for Windows before 6.1.2240, Zed Entreprise for Windows (ANSSI qualification submission) before 6.1.2150, Zed Entreprise for Mac before 2.0.199, Zed Entreprise for Linux before 2.0.199, Zed Pro for Windows before 1.0.195, Zed Pro for Mac before 1.0.199, Zed Pro for Linux before 1.0.199, Zed Free for Windows before 1.0.195, Zed Free for Mac before 1.0.199, and Zed Free for Linux before 1.0.199. Analyzing a Zed container can lead to the disclosure of plaintext content of very small files (a few bytes) stored into it.
CVE-2018-19279 2 Microsoft, Primx 2 Windows, Zonecentral 2024-11-21 N/A
PRIMX ZoneCentral before 6.1.2236 on Windows sometimes leaks the plaintext of NTFS files. On non-SSD devices, this is limited to a 5-second window and file sizes less than 600 bytes. The effect on SSD devices may be greater.