Filtered by vendor Tenda
Subscriptions
Total
1017 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-2805 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2025-01-24 | 8.8 High |
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been rated as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257660. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2991 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2025-01-22 | 6.3 Medium |
A vulnerability has been found in Tenda FH1203 2.0.1.6 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2992 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2892 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2893 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2894 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2895 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2896 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2897 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 6.3 Medium |
A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257940. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2899 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2898 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2900 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2901 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2902 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2891 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2560 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-22 | 4.3 Medium |
A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2581 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability. | ||||
CVE-2024-2903 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-57575 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-22 | 9.8 Critical |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. | ||||
CVE-2024-57583 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-22 | 9.8 Critical |
Tenda AC18 V15.03.05.19 was discovered to contain a command injection vulnerability via the usbName parameter in the formSetSambaConf function. |