Search Results (6 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-52548 2025-09-02 N/A
E3 Site Supervisor Control (firmware version < 2.31F01) contains a hidden API call in the application services that enables SSH and Shellinabox, which exist but are disabled by default. An attacker with admin access to the application services can utilize this API to enable remote access to the underlying OS.
CVE-2025-22450 2025-02-12 N/A
Inclusion of undocumented features issue exists in UD-LT2 firmware Ver.1.00.008_SE and earlier. A remote attacker may disable the LAN-side firewall function of the affected products, and open specific ports.
CVE-2024-52564 1 Iodata 2 Ud-lt1\/ex Firmware, Ud-lt1 Firmware 2025-01-29 N/A
Inclusion of undocumented features or chicken bits issue exists in UD-LT1 firmware Ver.2.1.8 and earlier and UD-LT1/EX firmware Ver.2.1.8 and earlier. A remote attacker may disable the firewall function of the affected products. As a result, an arbitrary OS command may be executed and/or configuration settings of the device may be altered.
CVE-2024-54457 2024-12-18 7.2 High
Inclusion of undocumented features or chicken bits issue exists in AE1021 firmware versions 2.0.10 and earlier and AE1021PE firmware versions 2.0.10 and earlier, which may allow a logged-in user to enable telnet service.
CVE-2024-2103 2024-11-21 6.5 Medium
Inclusion of undocumented features vulnerability accessible when logged on with a privileged access level on the following Schweitzer Engineering Laboratories relays could allow the relay to behave unpredictably: SEL-700BT Motor Bus Transfer Relay, SEL-700G Generator Protection Relay, SEL-710-5 Motor Protection Relay, SEL-751 Feeder Protection Relay, SEL-787-2/-3/-4 Transformer Protection Relay, SEL-787Z High-Impedance Differential Relay . See product instruction manual appendix A dated 20240308 for more details regarding the SEL-751 Feeder Protection Relay. For more information for the other affected products, see their instruction manuals dated 20240329.
CVE-2024-7011 2024-11-05 6.5 Medium
Sharp NEC Projectors (NP-CB4500UL, NP-CB4500WL, NP-CB4700UL, NP-P525UL, NP-P525UL+, NP-P525ULG, NP-P525ULJL, NP-P525WL, NP-P525WL+, NP-P525WLG, NP-P525WLJL, NP-CG6500UL, NP-CG6500WL, NP-CG6700UL, NP-P605UL, NP-P605UL+, NP-P605ULG, NP-P605ULJL, NP-CA4120X, NP-CA4160W, NP-CA4160X, NP-CA4200U, NP-CA4200W, NP-CA4202W, NP-CA4260X, NP-CA4300X, NP-CA4355X, NP-CD2100U, NP-CD2120X, NP-CD2300X, NP-CR2100X, NP-CR2170W, NP-CR2170X, NP-CR2200U, NP-CR2200W, NP-CR2280X, NP-CR2310X, NP-CR2350X, NP-MC302XG, NP-MC332WG, NP-MC332WJL, NP-MC342XG, NP-MC372X, NP-MC372XG, NP-MC382W, NP-MC382WG, NP-MC422XG, NP-ME342UG, NP-ME372W, NP-ME372WG, NP-ME372WJL, NP-ME382U, NP-ME382UG, NP-ME382UJL, NP-ME402X, NP-ME402XG, NP-ME402XJL, NP-CB4500XL, NP-CG6400UL, NP-CG6400WL, NP-CG6500XL, NP-PE455UL, NP-PE455ULG, NP-PE455WL, NP-PE455WLG, NP-PE505XLG, NP-CB4600U, NP-CF6600U, NP-P474U, NP-P554U, NP-P554U+, NP-P554UG, NP-P554UJL, NP-CG6600UL, NP-P547UL, NP-P547ULG, NP-P547ULJL, NP-P607UL+, NP-P627UL, NP-P627UL+, NP-P627ULG, NP-P627ULJL, NP-PV710UL-B, NP-PV710UL-B1, NP-PV710UL-W, NP-PV710UL-W+, NP-PV710UL-W1, NP-PV730UL-BJL, NP-PV730UL-WJL, NP-PV800UL-B, NP-PV800UL-B+, NP-PV800UL-B1, NP-PV800UL-BJL, NP-PV800UL-W, NP-PV800UL-W+, NP-PV800UL-W1, NP-PV800UL-WJL, NP-CA4200X, NP-CA4265X, NP-CA4300U, NP-CA4300W, NP-CA4305X, NP-CA4400X, NP-CD2125X, NP-CD2200W, NP-CD2300U, NP-CD2310X, NP-CR2105X, NP-CR2200X, NP-CR2205W, NP-CR2300U, NP-CR2300W, NP-CR2315X, NP-CR2400X, NP-MC333XG, NP-MC363XG, NP-MC393WJL, NP-MC423W, NP-MC423WG, NP-MC453X, NP-MC453X, NP-MC453XG, NP-MC453XJL, NP-ME383WG, NP-ME403U, NP-ME403UG, NP-ME403UJL, NP-ME423W, NP-ME423WG, NP-ME423WJL, NP-ME453X, NP-ME453XG, NP-CB4400USL, NP-CB4400WSL, NP-CB4510UL, NP-CB4510WL, NP-CB4510XL, NP-CB4550USL, NP-CB6700UL, NP-CG6510UL, NP-PE456USL, NP-PE456USLG, NP-PE456USLJL, NP-PE456WSLG, NP-PE506UL, NP-PE506ULG, NP-PE506ULJL, NP-PE506WL, NP-PE506WLG, NP-PE506WLJL) allows an attacker to cause a denial-of-service (DoS) condition via SNMP service.