CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
A vulnerability was identified in Cudy LT500E up to 2.3.12. Affected is an unknown function of the file /squashfs-root/etc/shadow of the component Web Interface. The manipulation leads to use of hard-coded password. The attack must be carried out locally. The attack's complexity is rated as high. The exploitability is told to be difficult. The exploit is publicly available and might be used. Upgrading to version 2.3.13 is able to address this issue. It is recommended to upgrade the affected component. The vendor explains: "[T]he firmware does store a default password of 'admin'. This password has been deprecated since LT500E firmware version 2.3.13 and is no longer used. The LT500E does not have an administrator password set by default; a new password (at least 8 characters ) must be manually created upon first login the web management page." |
A vulnerability was found in Intelbras InControl up to 2.21.59. It has been classified as problematic. Affected is an unknown function of the component Dispositivos Edição Page. The manipulation of the argument Senha de Comunicação leads to unprotected storage of credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. According to the vendor this issue should be fixed in a later release. |
The Group Policy implementation in Microsoft Windows Vista SP2, Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8, Windows 8.1, and Windows Server 2012 Gold and R2 does not properly handle distribution of passwords, which allows remote authenticated users to obtain sensitive credential information and consequently gain privileges by leveraging access to the SYSVOL share, as exploited in the wild in May 2014, aka "Group Policy Preferences Password Elevation of Privilege Vulnerability." |
A vulnerability was found in saltbo zpan up to 1.6.5/1.7.0-beta2. It has been rated as problematic. This issue affects the function NewToken of the file zpan/internal/app/service/token.go of the component JSON Web Token Handler. The manipulation with the input 123 leads to use of hard-coded password. The attack may be initiated remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. |
A vulnerability was found in Teledyne FLIR FB-Series O and FLIR FH-Series ID 1.3.2.16. It has been classified as problematic. This affects an unknown part. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
A vulnerability, which was classified as problematic, was found in D-Link DCS-7517 up to 2.02.0. This affects the function g_F_n_GenPassForQlync of the file /bin/httpd of the component Qlync Password Generation Handler. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer. |
A vulnerability, which was classified as problematic, was found in Done-0 Jank up to 322caebbad10568460364b9667aa62c3080bfc17. Affected is an unknown function of the file internal/utils/jwt_utils.go of the component JWT Token Handler. The manipulation of the argument accessSecret/refreshSecret with the input jank-blog-secret/jank-blog-refresh-secret leads to use of hard-coded password. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. |
A vulnerability, which was classified as problematic, has been found in mao888 bluebell-plus up to 2.3.0. This issue affects some unknown processing of the file bluebell_backend/pkg/jwt/jwt.go of the component JWT Token Handler. The manipulation of the argument mySecret with the input bluebell-plus leads to use of hard-coded password. The attack may be initiated remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. |
The Carlo Gavazzi
EOS-Box
stores hard-coded passwords in the PHP file of
the device. By using the hard-coded passwords, attackers can log into
the device with administrative privileges. This could allow the attacker
to have unauthorized access. |
WellinTech KingSCADA 3.0 uses a cleartext base64 format for storage of passwords in user.db, which allows context-dependent attackers to obtain sensitive information by reading this file. |
The potential exists for exposure of the product's password used to restrict unauthorized access to Rockwell PLC5/SLC5/0x/RSLogix 1785-Lx and 1747-L5x controllers. The potential exists for an unauthorized programming and configuration client to gain access to the product and allow changes to the product’s configuration or program. When applicable, upgrade product firmware to a version that includes enhanced security functionality compatible with Rockwell Automation's FactoryTalk Security services. |
A vulnerability, which was classified as problematic, has been found in TOTOLINK T10 4.1.8cu.5207. Affected by this issue is some unknown functionality of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. The attack can only be initiated within the local network. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. |
The PAM module for fscrypt doesn't adequately validate fscrypt metadata files, allowing users to create malicious metadata files that prevent other users from logging in. A local user can cause a denial of service by creating a fscrypt metadata file that prevents other users from logging into the system. We recommend upgrading to version 0.3.3 or above |
Sierra Wireless GX 440 devices with ALEOS firmware 4.3.2 have weak passwords for admin, rauser, sconsole, and user. |
A Plaintext Storage of a Password issue was discovered in Kabona AB WebDatorCentral (WDC) versions prior to Version 3.4.0. WDC stores password credentials in plaintext. |
ZyXEL PK5001Z devices have zyad5001 as the su password, which makes it easier for remote attackers to obtain root access if a non-root account password is known (or a non-root default account exists within an ISP's deployment of these devices). |
MultiTech FaxFinder before 4.1.2 stores Passwords unencrypted for maintaining the test connectivity function of its LDAP configuration. These credentials are retrieved by the system when the LDAP configuration page is opened and are embedded directly into the HTML source code in cleartext. |
IBM BigFix Inventory v9 9.2 stores user credentials in plain in clear text which can be read by a local user. |
Sierra Wireless GX 440 devices with ALEOS firmware 4.3.2 store passwords in cleartext. |
The Embedded Jopr component in JBoss Application Server includes the cleartext datasource password in unspecified HTML responses, which might allow (1) man-in-the-middle attackers to obtain sensitive information by leveraging failure to use SSL or (2) attackers to obtain sensitive information by reading the HTML source code. NOTE: the vendor says that this does not cross a trust boundary and that it is recommended best-practice that SSL is configured for the administrative console |