Description
An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. User credentials are sent to the web server using the HTTP GET method, which may result in the credentials being logged. This could make user credentials available for unauthorized retrieval.
Published: 2017-06-30
Score: 9.8 Critical
EPSS: 3.5% Low
KEV: No
Impact: n/a
Action: n/a
AI Analysis

No analysis available yet.

Remediation

No remediation available yet.

Tracking

Sign in to view the affected projects.

Advisories
Source ID Title
EUVD EUVD EUVD-2017-16870 An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. User credentials are sent to the web server using the HTTP GET method, which may result in the credentials being logged. This could make user credentials available for unauthorized retrieval.
History

No history.

Subscriptions

Rockwellautomation 1763-l16awa Series A 1763-l16awa Series B 1763-l16bbb Series A 1763-l16bbb Series B 1763-l16bwa Series A 1763-l16bwa Series B 1763-l16dwd Series A 1763-l16dwd Series B 1766-l32awa Series A 1766-l32awa Series B 1766-l32awaa Series A 1766-l32awaa Series B 1766-l32bwa Series A 1766-l32bwa Series B 1766-l32bwaa Series A 1766-l32bwaa Series B 1766-l32bxb Series A 1766-l32bxb Series B 1766-l32bxba Series A 1766-l32bxba Series B Ab Micrologix Controller
cve-icon MITRE

Status: PUBLISHED

Assigner: icscert

Published:

Updated: 2024-08-05T16:19:28.551Z

Reserved: 2017-04-18T00:00:00.000Z

Link: CVE-2017-7899

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Deferred

Published: 2017-06-30T03:29:00.733

Modified: 2025-04-20T01:37:25.860

Link: CVE-2017-7899

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

No data.

Weaknesses