Description
AC6005 V200R006C10SPC200,AC6605 V200R006C10SPC200,AR1200 with software V200R005C10CP0582T, V200R005C10HP0581T, V200R005C20SPC026T,AR200 with software V200R005C20SPC026T,AR3200 V200R005C20SPC026T,CloudEngine 12800 with software V100R003C00, V100R005C00, V100R005C10, V100R006C00, V200R001C00,CloudEngine 5800 with software V100R003C00, V100R005C00, V100R005C10, V100R006C00, V200R001C00,CloudEngine 6800 with software V100R003C00, V100R005C00, V100R005C10, V100R006C00, V200R001C00,CloudEngine 7800 with software V100R003C00, V100R005C00, V100R005C10, V100R006C00, V200R001C00,CloudEngine 8800 with software V100R006C00, V200R001C00,E600 V200R008C00,S12700 with software V200R005C00, V200R006C00, V200R007C00, V200R008C00,S1700 with software V100R006C00, V100R007C00, V200R006C00,S2300 with software V100R005C00, V100R006C00, V100R006C03, V100R006C05, V200R003C00, V200R003C02, V200R003C10, V200R005C00, V200R005C01, V200R005C02, V200R005C03, V200R006C00, V200R007C00, V200R008C00,S2700 with software V100R005C00, V100R006C00, V100R006C03, V100R006C05, V200R003C00, V200R003C02, V200R003C10, V200R005C00, V200R005C01, V200R005C02, V200R005C03, V200R006C00, V200R007C00, V200R008C00,S5300 with software V100R005C00, V100R006C00, V100R006C01, V200R001C00, V200R001C01, V200R002C00, V200R003C00, V200R003C02, V200R003C10, V200R005C00, V200R006C00, V200R007C00, V200R008C00,S5700 with software V100R005C00, V100R006C00, V100R006C01, V200R001C00, V200R001C01, V200R002C00, V200R003C00, V200R003C02, V200R003C10, V200R005C00, V200R006C00, V200R007C00, V200R008C00,S6300 with software V100R006C00, V200R001C00, V200R001C01, V200R002C00, V200R003C00, V200R003C02, V200R003C10, V200R005C00, V200R008C00,S6700 with software V100R006C00, V200R001C00, V200R001C01, V200R002C00, V200R003C00, V200R003C02, V200R003C10, V200R005C00, V200R006C00, V200R007C00, V200R008C00,S7700 with software V100R003C00, V100R006C00, V200R001C00, V200R001C01, V200R002C00, V200R003C00, V200R005C00, V200R006C00, V200R007C00, V200R008C00,S9300 with software V100R001C00, V100R002C00, V100R003C00, V100R006C00, V200R001C00, V200R002C00, V200R003C00, V200R005C00, V200R006C00, V200R007C00, V200R008C00, V200R008C10,S9700 with software V200R001C00, V200R002C00, V200R003C00, V200R005C00, V200R006C00, V200R007C00, V200R008C00,Secospace USG6600 V500R001C00SPC050 have a MaxAge LSA vulnerability due to improper OSPF implementation. When the device receives special LSA packets, the LS (Link Status) age would be set to MaxAge, 3600 seconds. An attacker can exploit this vulnerability to poison the route table and launch a DoS attack.
Published: 2017-11-22
Score: 7.5 High
EPSS: < 1% Very Low
KEV: No
Impact: n/a
Action: n/a
AI Analysis

No analysis available yet.

Remediation

No remediation available yet.

Tracking

Sign in to view the affected projects.

Advisories
Source ID Title
EUVD EUVD EUVD-2017-17109 AC6005 V200R006C10SPC200,AC6605 V200R006C10SPC200,AR1200 with software V200R005C10CP0582T, V200R005C10HP0581T, V200R005C20SPC026T,AR200 with software V200R005C20SPC026T,AR3200 V200R005C20SPC026T,CloudEngine 12800 with software V100R003C00, V100R005C00, V100R005C10, V100R006C00, V200R001C00,CloudEngine 5800 with software V100R003C00, V100R005C00, V100R005C10, V100R006C00, V200R001C00,CloudEngine 6800 with software V100R003C00, V100R005C00, V100R005C10, V100R006C00, V200R001C00,CloudEngine 7800 with software V100R003C00, V100R005C00, V100R005C10, V100R006C00, V200R001C00,CloudEngine 8800 with software V100R006C00, V200R001C00,E600 V200R008C00,S12700 with software V200R005C00, V200R006C00, V200R007C00, V200R008C00,S1700 with software V100R006C00, V100R007C00, V200R006C00,S2300 with software V100R005C00, V100R006C00, V100R006C03, V100R006C05, V200R003C00, V200R003C02, V200R003C10, V200R005C00, V200R005C01, V200R005C02, V200R005C03, V200R006C00, V200R007C00, V200R008C00,S2700 with software V100R005C00, V100R006C00, V100R006C03, V100R006C05, V200R003C00, V200R003C02, V200R003C10, V200R005C00, V200R005C01, V200R005C02, V200R005C03, V200R006C00, V200R007C00, V200R008C00,S5300 with software V100R005C00, V100R006C00, V100R006C01, V200R001C00, V200R001C01, V200R002C00, V200R003C00, V200R003C02, V200R003C10, V200R005C00, V200R006C00, V200R007C00, V200R008C00,S5700 with software V100R005C00, V100R006C00, V100R006C01, V200R001C00, V200R001C01, V200R002C00, V200R003C00, V200R003C02, V200R003C10, V200R005C00, V200R006C00, V200R007C00, V200R008C00,S6300 with software V100R006C00, V200R001C00, V200R001C01, V200R002C00, V200R003C00, V200R003C02, V200R003C10, V200R005C00, V200R008C00,S6700 with software V100R006C00, V200R001C00, V200R001C01, V200R002C00, V200R003C00, V200R003C02, V200R003C10, V200R005C00, V200R006C00, V200R007C00, V200R008C00,S7700 with software V100R003C00, V100R006C00, V200R001C00, V200R001C01, V200R002C00, V200R003C00, V200R005C00, V200R006C00, V200R007C00, V200R008C00,S9300 with software V100R001C00, V100R002C00, V100R003C00, V100R006C00, V200R001C00, V200R002C00, V200R003C00, V200R005C00, V200R006C00, V200R007C00, V200R008C00, V200R008C10,S9700 with software V200R001C00, V200R002C00, V200R003C00, V200R005C00, V200R006C00, V200R007C00, V200R008C00,Secospace USG6600 V500R001C00SPC050 have a MaxAge LSA vulnerability due to improper OSPF implementation. When the device receives special LSA packets, the LS (Link Status) age would be set to MaxAge, 3600 seconds. An attacker can exploit this vulnerability to poison the route table and launch a DoS attack.
History

No history.

Subscriptions

Huawei Ac6005 Ac6005 Firmware Ac6605 Ac6605 Firmware Ar1200 Ar1200 Firmware Ar200 Ar200 Firmware Ar3200 Ar3200 Firmware Cloudengine 12800 Cloudengine 12800 Firmware Cloudengine 5800 Cloudengine 5800 Firmware Cloudengine 6800 Cloudengine 6800 Firmware Cloudengine 7800 Cloudengine 7800 Firmware Cloudengine 8800 Cloudengine 8800 Firmware E600 E600 Firmware S12700 S12700 Firmware S1700 S1700 Firmware S2300 S2300 Firmware S2700 S2700 Firmware S5300 S5300 Firmware S5700 S5700 Firmware S6300 S6300 Firmware S6700 S6700 Firmware S7700 S7700 Firmware S9300 S9300 Firmware S9700 S9700 Firmware Secospace Usg6600 Secospace Usg6600 Firmware
cve-icon MITRE

Status: PUBLISHED

Assigner: huawei

Published:

Updated: 2024-09-16T17:03:05.616Z

Reserved: 2017-04-25T00:00:00.000Z

Link: CVE-2017-8147

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Deferred

Published: 2017-11-22T19:29:03.257

Modified: 2025-04-20T01:37:25.860

Link: CVE-2017-8147

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

No data.

Weaknesses