An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer account, allows changing very sensitive parameters. NOTE: the vendor reports that Grid Guard is not an authentication feature; it is only a tracing feature. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Project Subscriptions
| Vendors | Products |
|---|---|
|
Sma
Subscribe
|
Sunny Boy 1.5
Subscribe
Sunny Boy 1.5 Firmware
Subscribe
Sunny Boy 2.5
Subscribe
Sunny Boy 2.5 Firmware
Subscribe
Sunny Boy 3.0
Subscribe
Sunny Boy 3.0 Firmware
Subscribe
Sunny Boy 3.6
Subscribe
Sunny Boy 3.6 Firmware
Subscribe
Sunny Boy 3000tl
Subscribe
Sunny Boy 3000tl Firmware
Subscribe
Sunny Boy 3600
Subscribe
Sunny Boy 3600 Firmware
Subscribe
Sunny Boy 3600tl
Subscribe
Sunny Boy 3600tl Firmware
Subscribe
Sunny Boy 4.0
Subscribe
Sunny Boy 4.0 Firmware
Subscribe
Sunny Boy 4000tl
Subscribe
Sunny Boy 4000tl Firmware
Subscribe
Sunny Boy 5.0
Subscribe
Sunny Boy 5.0 Firmware
Subscribe
Sunny Boy 5000
Subscribe
Sunny Boy 5000 Firmware
Subscribe
Sunny Boy 5000tl
Subscribe
Sunny Boy 5000tl Firmware
Subscribe
Sunny Boy Storage 2.5
Subscribe
Sunny Boy Storage 2.5 Firmware
Subscribe
Sunny Central 1000cp Xt
Subscribe
Sunny Central 1000cp Xt Firmware
Subscribe
Sunny Central 2200
Subscribe
Sunny Central 2200 Firmware
Subscribe
Sunny Central 500cp Xt
Subscribe
Sunny Central 500cp Xt Firmware
Subscribe
Sunny Central 630cp Xt
Subscribe
Sunny Central 630cp Xt Firmware
Subscribe
Sunny Central 720cp Xt
Subscribe
Sunny Central 720cp Xt Firmware
Subscribe
Sunny Central 760cp Xt
Subscribe
Sunny Central 760cp Xt Firmware
Subscribe
Sunny Central 800cp Xt
Subscribe
Sunny Central 800cp Xt Firmware
Subscribe
Sunny Central 850cp Xt
Subscribe
Sunny Central 850cp Xt Firmware
Subscribe
Sunny Central 900cp Xt
Subscribe
Sunny Central 900cp Xt Firmware
Subscribe
Sunny Central Storage 1000
Subscribe
Sunny Central Storage 1000 Firmware
Subscribe
Sunny Central Storage 2200
Subscribe
Sunny Central Storage 2200 Firmware
Subscribe
Sunny Central Storage 2500-ev
Subscribe
Sunny Central Storage 2500-ev Firmware
Subscribe
Sunny Central Storage 500
Subscribe
Sunny Central Storage 500 Firmware
Subscribe
Sunny Central Storage 630
Subscribe
Sunny Central Storage 630 Firmware
Subscribe
Sunny Central Storage 720
Subscribe
Sunny Central Storage 720 Firmware
Subscribe
Sunny Central Storage 760
Subscribe
Sunny Central Storage 760 Firmware
Subscribe
Sunny Central Storage 800
Subscribe
Sunny Central Storage 800 Firmware
Subscribe
Sunny Central Storage 850
Subscribe
Sunny Central Storage 850 Firmware
Subscribe
Sunny Central Storage 900
Subscribe
Sunny Central Storage 900 Firmware
Subscribe
Sunny Tripower 12000tl
Subscribe
Sunny Tripower 12000tl Firmware
Subscribe
Sunny Tripower 15000tl
Subscribe
Sunny Tripower 15000tl Firmware
Subscribe
Sunny Tripower 20000tl
Subscribe
Sunny Tripower 20000tl Firmware
Subscribe
Sunny Tripower 25000tl
Subscribe
Sunny Tripower 25000tl Firmware
Subscribe
Sunny Tripower 5000tl
Subscribe
Sunny Tripower 5000tl Firmware
Subscribe
Sunny Tripower 60
Subscribe
Sunny Tripower 60 Firmware
Subscribe
Sunny Tripower Core1
Subscribe
Sunny Tripower Core1 Firmware
Subscribe
|
Advisories
No advisories yet.
Fixes
Solution
No solution given by the vendor.
Workaround
No workaround given by the vendor.
References
History
Tue, 29 Oct 2024 15:00:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Weaknesses | CWE-284 |
Tue, 29 Oct 2024 14:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Weaknesses | CWE-863 | |
| Metrics |
ssvc
|
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: mitre
Published:
Updated: 2024-10-29T13:57:15.277Z
Reserved: 2017-06-24T00:00:00
Link: CVE-2017-9855
Updated: 2024-08-05T17:18:02.233Z
Status : Deferred
Published: 2017-08-05T17:29:00.553
Modified: 2025-04-20T01:37:25.860
Link: CVE-2017-9855
No data.
OpenCVE Enrichment
No data.
Weaknesses