Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:cisco:vbond_orchestrator:-:*:*:*:*:*:*:*", "matchCriteriaId": "BA648664-0734-4D02-8944-CA4DF4D756D6", "vulnerable": true}, {"criteria": "cpe:2.3:a:cisco:vedge-plus:-:*:*:*:*:*:*:*", "matchCriteriaId": "8828CED0-5B61-4BC9-B222-2295507E5FB7", "vulnerable": true}, {"criteria": "cpe:2.3:a:cisco:vedge-pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "937B8016-77E1-4F8C-8701-6AFFE36F6A49", "vulnerable": true}, {"criteria": "cpe:2.3:a:cisco:vmanage_network_management:-:*:*:*:*:*:*:*", "matchCriteriaId": "DDF9528B-1D1E-4CF2-ABA8-D01CC6F4A8BD", "vulnerable": true}, {"criteria": "cpe:2.3:a:cisco:vsmart_controller:-:*:*:*:*:*:*:*", "matchCriteriaId": "2F16884C-A2EE-4867-8806-6418E000078C", "vulnerable": true}], "negate": false, "operator": "OR"}]}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:cisco:vedge-100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07BDB466-E5FC-40FF-8400-836551AD4AE5", "versionEndExcluding": "18.3.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:cisco:vedge-100:-:*:*:*:*:*:*:*", "matchCriteriaId": "5D71E4AF-6E91-4493-A591-4D056D0E59C1", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:cisco:vedge_100b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "493ED5A7-3F08-4C2B-8259-F945088C42C4", "versionEndExcluding": "18.3.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:cisco:vedge_100b:-:*:*:*:*:*:*:*", "matchCriteriaId": "0811E0B5-889E-451E-B754-A8FEE32BDFA2", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:cisco:vedge_100m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A89574B-5FA1-45D2-92F5-E6AE60B21AAC", "versionEndExcluding": "18.3.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:cisco:vedge_100m:-:*:*:*:*:*:*:*", "matchCriteriaId": "36973815-F46D-4ADA-B9DF-BCB70AC60BD3", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:cisco:vedge_100wm_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A124EBDB-1E4D-44FF-8647-342ACB7FC536", "versionEndExcluding": "18.3.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:cisco:vedge_100wm:-:*:*:*:*:*:*:*", "matchCriteriaId": "061A302C-8D35-4E80-93DA-916DA7E90C06", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:cisco:vedge-1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F33875D3-8A95-4201-B385-FA63CCDBE103", "versionEndExcluding": "18.3.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:cisco:vedge-1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "F718A859-BCDB-4DD0-819D-60ABE710F0A9", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:cisco:vedge-2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D486E57-9E41-4744-AB0C-56B706B6989C", "versionEndExcluding": "18.3.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:cisco:vedge-2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "52EEF288-492C-4CE6-A082-631005C5E711", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:cisco:vedge-5000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C78995CF-3005-496D-A168-F9EEF09EEF44", "versionEndExcluding": "18.3.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:cisco:vedge-5000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C0C5E2C9-7D4B-405C-93DD-33DF265131E2", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "A vulnerability in the Zero Touch Provisioning (ZTP) subsystem of the Cisco SD-WAN Solution could allow an authenticated, local attacker to inject arbitrary commands that are executed with root privileges. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by authenticating to the device and submitting malicious input to the affected parameter. The attacker must be authenticated to access the affected parameter. A successful exploit could allow an attacker to execute commands with root privileges. This vulnerability affects the following Cisco products if they are running a release of the Cisco SD-WAN Solution prior to Release 18.3.0: vEdge 100 Series Routers, vEdge 1000 Series Routers, vEdge 2000 Series Routers, vEdge 5000 Series Routers. Cisco Bug IDs: CSCvi69906."}, {"lang": "es", "value": "Una vulnerabilidad en el subsistema Zero Touch Provisioning (ZTP) de Cisco SD-WAN podr\u00eda permitir que un atacante local autenticado inyecte comandos arbitrarios que se ejecutan con privilegios root. Esta vulnerabilidad se debe a una validaci\u00f3n de entradas insuficiente. Un atacante podr\u00eda explotar esta vulnerabilidad autentic\u00e1ndose en el dispositivo y enviando entradas maliciosas al par\u00e1metro afectado. El atacante debe estar autenticado para acceder al par\u00e1metro afectado. Su explotaci\u00f3n con \u00e9xito podr\u00eda permitir que el atacante ejecute comandos con privilegios root. Esta vulnerabilidad afecta a los siguientes productos Cisco si est\u00e1n ejecutando una versi\u00f3n de Cisco SD-WAN Solution anterior a la 18.3.0: vEdge 100 Series Routers, vEdge 1000 Series Routers, vEdge 2000 Series Routers y vEdge 5000 Series Routers. Cisco Bug IDs: CSCvi69906."}], "id": "CVE-2018-0347", "lastModified": "2024-11-21T03:38:01.850", "metrics": {"cvssMetricV2": [{"acInsufInfo": true, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0"}, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV30": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2018-07-18T23:29:00.493", "references": [{"source": "ykramarz@cisco.com", "tags": ["Third Party Advisory", "VDB Entry"], "url": "http://www.securityfocus.com/bid/104862"}, {"source": "ykramarz@cisco.com", "tags": ["Vendor Advisory"], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180718-sdwan-ci"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory", "VDB Entry"], "url": "http://www.securityfocus.com/bid/104862"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180718-sdwan-ci"}], "sourceIdentifier": "ykramarz@cisco.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-77"}], "source": "ykramarz@cisco.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-77"}], "source": "nvd@nist.gov", "type": "Primary"}]}