Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:philips:e-alert_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A20F1AAF-D947-4713-AB4E-12364592DBA3", "versionEndIncluding": "r2.1", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "descriptions": [{"lang": "en", "value": "Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data."}, {"lang": "es", "value": "Philips e-Alert Unit (dispositivo no m\u00e9dico), versiones R2.1 y anteriores. El software contiene una clave criptogr\u00e1fica embebida, que emplea para cifrar los datos internos."}], "id": "CVE-2018-8856", "lastModified": "2024-11-21T04:14:27.820", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0"}, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV30": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2018-09-26T19:29:03.347", "references": [{"source": "ics-cert@hq.dhs.gov", "tags": ["Third Party Advisory", "VDB Entry"], "url": "http://www.securityfocus.com/bid/105194"}, {"source": "ics-cert@hq.dhs.gov", "tags": ["Mitigation", "Third Party Advisory", "US Government Resource"], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01"}, {"source": "ics-cert@hq.dhs.gov", "tags": ["Vendor Advisory"], "url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory", "VDB Entry"], "url": "http://www.securityfocus.com/bid/105194"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Mitigation", "Third Party Advisory", "US Government Resource"], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"}], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-798"}], "source": "nvd@nist.gov", "type": "Primary"}]}