The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI.
Project Subscriptions
| Vendors | Products |
|---|---|
|
Ibm
Subscribe
|
Bladecenter Hs22
Subscribe
Bladecenter Hs22 Firmware
Subscribe
Bladecenter Hs23
Subscribe
Bladecenter Hs23 Firmware
Subscribe
Bladecenter Hs23e
Subscribe
Bladecenter Hs23e Firmware
Subscribe
Flex System X220 M4
Subscribe
Flex System X220 M4 Firmware
Subscribe
Flex System X222 M4
Subscribe
Flex System X222 M4 Firmware
Subscribe
Flex System X240 M4
Subscribe
Flex System X240 M4 Firmware
Subscribe
Flex System X280 M4
Subscribe
Flex System X280 M4 Firmware
Subscribe
Flex System X440 M4
Subscribe
Flex System X440 M4 Firmware
Subscribe
Flex System X480 M4
Subscribe
Flex System X480 M4 Firmware
Subscribe
Flex System X880 M4
Subscribe
Flex System X880 M4 Firmware
Subscribe
Idataplex Dx360 M4
Subscribe
Idataplex Dx360 M4 Firmware
Subscribe
Idataplex Dx360 M4 Water Cooled
Subscribe
Idataplex Dx360 M4 Water Cooled Firmware
Subscribe
Nextscale Nx360 M4
Subscribe
Nextscale Nx360 M4 Firmware
Subscribe
System X3100 M4
Subscribe
System X3100 M4 Firmware
Subscribe
System X3100 M5
Subscribe
System X3100 M5 Firmware
Subscribe
System X3250 M4
Subscribe
System X3250 M4 Firmware
Subscribe
System X3250 M5
Subscribe
System X3250 M5 Firmware
Subscribe
System X3300 M4
Subscribe
System X3300 M4 Firmware
Subscribe
System X3500 M4
Subscribe
System X3500 M4 Firmware
Subscribe
System X3530 M4
Subscribe
System X3530 M4 Firmware
Subscribe
System X3550 M4
Subscribe
System X3550 M4 Firmware
Subscribe
System X3630 M4
Subscribe
System X3630 M4 Firmware
Subscribe
System X3650 M4
Subscribe
System X3650 M4 Bd
Subscribe
System X3650 M4 Bd Firmware
Subscribe
System X3650 M4 Firmware
Subscribe
System X3650 M4 Hd
Subscribe
System X3650 M4 Hd Firmware
Subscribe
System X3750 M4
Subscribe
System X3750 M4 Firmware
Subscribe
System X3850 X6
Subscribe
System X3850 X6 Firmware
Subscribe
System X3950 X6
Subscribe
System X3950 X6 Firmware
Subscribe
|
|
Lenovo
Subscribe
|
Flex System X240 M4
Subscribe
Flex System X240 M4 Firmware
Subscribe
Flex System X240 M5
Subscribe
Flex System X240 M5 Firmware
Subscribe
Flex System X280 X6
Subscribe
Flex System X280 X6 Firmware
Subscribe
Flex System X440 M4
Subscribe
Flex System X440 M4 Firmware
Subscribe
Flex System X480 X6
Subscribe
Flex System X480 X6 Firmware
Subscribe
Flex System X880
Subscribe
Flex System X880 Firmware
Subscribe
Nextscale Nx360 M5
Subscribe
Nextscale Nx360 M5 Firmware
Subscribe
System X3250 M6
Subscribe
System X3250 M6 Firmware
Subscribe
System X3500 M5
Subscribe
System X3500 M5 Firmware
Subscribe
System X3550 M5
Subscribe
System X3550 M5 Firmware
Subscribe
System X3650 M5
Subscribe
System X3650 M5 Firmware
Subscribe
System X3750 M4
Subscribe
System X3750 M4 Firmware
Subscribe
System X3850 X6
Subscribe
System X3850 X6 Firmware
Subscribe
System X3950 X6
Subscribe
System X3950 X6 Firmware
Subscribe
|
Advisories
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2018-20671 | The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI. |
Fixes
Solution
No solution given by the vendor.
Workaround
No workaround given by the vendor.
References
| Link | Providers |
|---|---|
| https://support.lenovo.com/us/en/solutions/LEN-20227 |
|
History
No history.
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: lenovo
Published:
Updated: 2024-09-17T03:38:52.294Z
Reserved: 2018-03-27T00:00:00
Link: CVE-2018-9068
No data.
Status : Modified
Published: 2018-07-26T19:29:00.487
Modified: 2024-11-21T04:14:54.413
Link: CVE-2018-9068
No data.
OpenCVE Enrichment
No data.
Weaknesses
EUVD