Barco wePresent WiPG-1600W devices have Improper Access Control. Affected Version(s): 2.5.1.8. The Barco wePresent WiPG-1600W device has an SSH daemon included in the firmware image. By default, the SSH daemon is disabled and does not start at system boot. The system initialization scripts read a device configuration file variable to see if the SSH daemon should be started. The web interface does not provide a visible capability to alter this configuration file variable. However, a malicious actor can include this variable in a POST such that the SSH daemon will be started when the device boots.
Metrics
Affected Vendors & Products
References
History
No history.
MITRE
Status: PUBLISHED
Assigner: mitre
Published: 2020-11-24T17:38:53
Updated: 2024-08-04T16:33:58.749Z
Reserved: 2020-11-06T00:00:00
Link: CVE-2020-28331
Vulnrichment
No data.
NVD
Status : Modified
Published: 2020-11-24T18:15:12.127
Modified: 2024-11-21T05:22:35.547
Link: CVE-2020-28331
Redhat
No data.