Barco wePresent WiPG-1600W devices have Improper Access Control. Affected Version(s): 2.5.1.8. The Barco wePresent WiPG-1600W device has an SSH daemon included in the firmware image. By default, the SSH daemon is disabled and does not start at system boot. The system initialization scripts read a device configuration file variable to see if the SSH daemon should be started. The web interface does not provide a visible capability to alter this configuration file variable. However, a malicious actor can include this variable in a POST such that the SSH daemon will be started when the device boots.
History

No history.

cve-icon MITRE

Status: PUBLISHED

Assigner: mitre

Published: 2020-11-24T17:38:53

Updated: 2024-08-04T16:33:58.749Z

Reserved: 2020-11-06T00:00:00

Link: CVE-2020-28331

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Analyzed

Published: 2020-11-24T18:15:12.127

Modified: 2022-07-12T17:42:04.277

Link: CVE-2020-28331

cve-icon Redhat

No data.