Metrics
Affected Vendors & Products
Solution
The following software releases have been updated to resolve this specific issue: 16.1R7-S8, 17.2R3-S4, 17.3R3-S8, 17.4R2-S11, 17.4R3-S2, 18.1R3-S10, 18.2R1, and all subsequent releases.
Workaround
If you are susceptible to this issue and unable to upgrade to software with the fix, you can deploy a workaround by disabling the “inline-flow” feature. To check for use and to disable the “inline-jflow” service on a device, see https://www.juniper.net/documentation/en_US/junos/topics/task/configuration/inline-flow-monitoring-ptx.html for additional details. Removing “inline-jflow” takes effect immediately and there is no need to restart the FPCs or the router. Once the feature is removed, the router no longer provides traffic data to the flow collector.
No history.

Status: PUBLISHED
Assigner: juniper
Published:
Updated: 2024-09-16T19:04:41.792Z
Reserved: 2020-10-27T00:00:00
Link: CVE-2021-0270

No data.

Status : Modified
Published: 2021-04-22T20:15:10.017
Modified: 2024-11-21T05:42:22.033
Link: CVE-2021-0270

No data.

No data.