Description
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.
No analysis available yet.
Remediation
No remediation available yet.
Tracking
Sign in to view the affected projects.
Advisories
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2021-12553 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition. |
References
History
No history.
Subscriptions
Siemens
Subscribe
Simatic Hmi Comfort Outdoor Panels 15\"
Subscribe
Simatic Hmi Comfort Outdoor Panels 15\" Firmware
Subscribe
Simatic Hmi Comfort Outdoor Panels 7\"
Subscribe
Simatic Hmi Comfort Outdoor Panels 7\" Firmware
Subscribe
Simatic Hmi Comfort Panels 22\"
Subscribe
Simatic Hmi Comfort Panels 22\" Firmware
Subscribe
Simatic Hmi Comfort Panels 4\"
Subscribe
Simatic Hmi Comfort Panels 4\" Firmware
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp400f
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp400f Firmware
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp700
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp700 Firmware
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp700f
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp700f Firmware
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp900
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp900 Firmware
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp900f
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp900f Firmware
Subscribe
Simatic Wincc Runtime Advanced
Subscribe
Status: PUBLISHED
Assigner: siemens
Published:
Updated: 2024-08-03T20:11:27.591Z
Reserved: 2021-01-21T00:00:00.000Z
Link: CVE-2021-25661
No data.
Status : Modified
Published: 2021-05-12T14:15:11.300
Modified: 2024-11-21T05:55:14.483
Link: CVE-2021-25661
No data.
OpenCVE Enrichment
No data.
Weaknesses
EUVD