Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F615F516-29EF-4C15-9E18-C5D4F6291A38", "versionEndExcluding": "1.0.0.58", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "4FD4ED11-4130-47DA-8A9D-55B8F6E3E213", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "NETGEAR XR1000 devices before 1.0.0.58 are affected by command injection by an unauthenticated attacker."}, {"lang": "es", "value": "Los dispositivos NETGEAR XR1000 versiones anteriores a 1.0.0.58, est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado"}], "id": "CVE-2021-45514", "lastModified": "2024-11-21T06:32:23.533", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": {"accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0"}, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2021-12-26T01:15:13.580", "references": [{"source": "cve@mitre.org", "tags": ["Vendor Advisory"], "url": "https://kb.netgear.com/000064154/Security-Advisory-for-Command-Injection-on-XR1000-PSV-2021-0018"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://kb.netgear.com/000064154/Security-Advisory-for-Command-Injection-on-XR1000-PSV-2021-0018"}], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-77"}], "source": "nvd@nist.gov", "type": "Primary"}]}