AutomationDirect DirectLOGIC has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73;
Advisories
Source ID Title
EUVD EUVD EUVD-2022-34312 AutomationDirect DirectLOGIC has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73;
Fixes

Solution

AutomationDirect recommends users upgrade to firmware Version 6.73 or later, which supports TLS security options for the webserver. While automation networks and systems have built-in password protection schemes, this is only one step in securing the affected systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products, and other SCADA system products perform independent network security analysis to determine the proper level of security required for the application. AutomationDirect has identified the following mitigations for instances where systems cannot be upgraded to Version 6.73 or later: The Webserver feature can be disabled on the HMI using the programming software. Place the HMI panel behind a VPN: Access to and from critical control system assets in the modern environment is usually LAN based, but still should be considered remote if the operator is traversing across different networks. virtual private networking (VPN) is often considered the best approach in securing trans-network communication.


Workaround

No workaround given by the vendor.

History

Wed, 16 Apr 2025 18:15:00 +0000

Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}


cve-icon MITRE

Status: PUBLISHED

Assigner: icscert

Published:

Updated: 2025-04-16T17:49:35.105Z

Reserved: 2022-06-06T00:00:00.000Z

Link: CVE-2022-2006

cve-icon Vulnrichment

Updated: 2024-08-03T00:24:44.035Z

cve-icon NVD

Status : Modified

Published: 2022-08-31T16:15:10.580

Modified: 2024-11-21T07:00:09.847

Link: CVE-2022-2006

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

No data.