{"containers": {"cna": {"providerMetadata": {"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens", "dateUpdated": "2023-10-10T10:21:02.321Z"}, "descriptions": [{"lang": "en", "value": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack."}], "affected": [{"vendor": "Siemens", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE M804PB", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE M812-1 ADSL-Router (Annex A)", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE M812-1 ADSL-Router (Annex B)", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE M816-1 ADSL-Router (Annex A)", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE M816-1 ADSL-Router (Annex B)", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE M826-2 SHDSL-Router", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE M874-2", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE M874-3", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE M876-3 (EVDO)", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE M876-3 (ROK)", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE M876-4 (EU)", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE M876-4 (NAM)", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE MUM853-1 (EU)", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE MUM856-1 (EU)", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE MUM856-1 (RoW)", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE S615", "versions": [{"version": "All versions < V7.1.2", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE SC622-2C", "versions": [{"version": "All versions < V2.3.1", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE SC626-2C", "versions": [{"version": "All versions < V2.3.1", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE SC632-2C", "versions": [{"version": "All versions < V2.3.1", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE SC636-2C", "versions": [{"version": "All versions < V2.3.1", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE SC642-2C", "versions": [{"version": "All versions < V2.3.1", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE SC646-2C", "versions": [{"version": "All versions < V2.3.1", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W1748-1 M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W1748-1 M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W1788-1 M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W1788-2 EEC M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W1788-2 M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W1788-2IA M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W721-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W721-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W722-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W722-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W722-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W734-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W734-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W734-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W734-1 RJ45 (USA)", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W738-1 M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W738-1 M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W748-1 M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W748-1 M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W748-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W748-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W761-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W761-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W774-1 M12 EEC", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W774-1 M12 EEC", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W774-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W774-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W774-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W774-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W774-1 RJ45 (USA)", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W778-1 M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W778-1 M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W778-1 M12 EEC", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W778-1 M12 EEC (USA)", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W786-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W786-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W786-2 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W786-2 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W786-2 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W786-2 SFP", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W786-2 SFP", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W786-2IA RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W786-2IA RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W788-1 M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W788-1 M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W788-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W788-1 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W788-2 M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W788-2 M12", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W788-2 M12 EEC", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W788-2 M12 EEC", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W788-2 M12 EEC", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W788-2 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W788-2 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE W788-2 RJ45", "versions": [{"version": "All versions", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE WAM763-1", "versions": [{"version": "All versions < V2.0", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE WAM766-1 (EU)", "versions": [{"version": "All versions < V2.0", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE WAM766-1 (US)", "versions": [{"version": "All versions < V2.0", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE WAM766-1 EEC (EU)", "versions": [{"version": "All versions < V2.0", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE WAM766-1 EEC (US)", "versions": [{"version": "All versions < V2.0", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE WUM763-1", "versions": [{"version": "All versions < V2.0", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE WUM763-1", "versions": [{"version": "All versions < V2.0", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE WUM766-1 (EU)", "versions": [{"version": "All versions < V2.0", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE WUM766-1 (US)", "versions": [{"version": "All versions < V2.0", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB205-3 (SC, PN)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB205-3 (ST, E/IP)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB205-3 (ST, E/IP)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB205-3 (ST, PN)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB205-3LD (SC, E/IP)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB205-3LD (SC, PN)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB208 (E/IP)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB208 (PN)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB213-3 (SC, E/IP)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB213-3 (SC, PN)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB213-3 (ST, E/IP)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB213-3 (ST, PN)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB213-3LD (SC, E/IP)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB213-3LD (SC, PN)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB216 (E/IP)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XB216 (PN)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC206-2 (SC)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC206-2 (ST/BFOC)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC206-2G PoE", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC206-2G PoE (54 V DC)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC206-2G PoE EEC (54 V DC)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC206-2SFP", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC206-2SFP EEC", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC206-2SFP G", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC206-2SFP G (EIP DEF.)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC206-2SFP G EEC", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC208", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC208EEC", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC208G", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC208G (EIP def.)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC208G EEC", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC208G PoE", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC208G PoE (54 V DC)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC216", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC216-3G PoE", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC216-3G PoE (54 V DC)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC216-4C", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC216-4C G", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC216-4C G (EIP Def.)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC216-4C G EEC", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC216EEC", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC224", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC224-4C G", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC224-4C G (EIP Def.)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XC224-4C G EEC", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XF204", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XF204 DNA", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XF204-2BA", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XF204-2BA DNA", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XM408-4C", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XM408-4C (L3 int.)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XM408-8C", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XM408-8C (L3 int.)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XM416-4C", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XM416-4C (L3 int.)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XP208", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XP208 (Ethernet/IP)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XP208EEC", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XP208PoE EEC", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XP216", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XP216 (Ethernet/IP)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XP216EEC", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XP216POE EEC", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR326-2C PoE WG", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR326-2C PoE WG (without UL)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR524-8C, 1x230V", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR524-8C, 24V", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR524-8C, 24V (L3 int.)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR524-8C, 2x230V", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR526-8C, 1x230V", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR526-8C, 24V", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR526-8C, 24V (L3 int.)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR526-8C, 2x230V", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR528-6M", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR528-6M (2HR2)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR528-6M (L3 int.)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR552-12M", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR552-12M (2HR2)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SCALANCE XR552-12M (2HR2)", "versions": [{"version": "All versions < V6.6", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SIPLUS NET SCALANCE XC206-2", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SIPLUS NET SCALANCE XC206-2SFP", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SIPLUS NET SCALANCE XC208", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "SIPLUS NET SCALANCE XC216-4C", "versions": [{"version": "All versions < V4.4", "status": "affected"}], "defaultStatus": "unknown"}], "metrics": [{"cvssV3_1": {"version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "baseScore": 7.5, "baseSeverity": "HIGH"}}], "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-770", "description": "CWE-770: Allocation of Resources Without Limits or Throttling", "type": "CWE"}]}], "references": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"}]}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T10:00:04.354Z"}, "title": "CVE Program Container", "references": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf", "tags": ["x_transferred"]}]}]}, "cveMetadata": {"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-36324", "datePublished": "2022-08-10T11:18:39", "dateReserved": "2022-07-20T00:00:00", "dateUpdated": "2024-08-03T10:00:04.354Z", "state": "PUBLISHED"}, "dataType": "CVE_RECORD", "dataVersion": "5.1"}