Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.
Metrics
Affected Vendors & Products
References
History
No history.
MITRE
Status: PUBLISHED
Assigner: zdi
Published: 2024-05-03T01:59:27.382Z
Updated: 2024-08-02T18:10:20.680Z
Reserved: 2023-08-02T21:37:23.122Z
Link: CVE-2023-39464
Vulnrichment
Updated: 2024-08-02T18:10:20.680Z
NVD
Status : Awaiting Analysis
Published: 2024-05-03T03:15:11.870
Modified: 2024-05-03T12:50:12.213
Link: CVE-2023-39464
Redhat