Show plain JSON{"dataType": "CVE_RECORD", "containers": {"adp": [{"title": "CISA ADP Vulnrichment", "metrics": [{"other": {"type": "ssvc", "content": {"id": "CVE-2023-42667", "role": "CISA Coordinator", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "version": "2.0.3", "timestamp": "2024-08-14T15:09:41.938025Z"}}}], "affected": [{"cpes": ["cpe:2.3:h:intel:core_ultra_processor:*:*:*:*:*:*:*:*"], "vendor": "intel", "product": "core_ultra_processor", "versions": [{"status": "affected", "version": "0", "lessThan": "microcode-20240813", "versionType": "git"}], "defaultStatus": "unaffected"}], "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-08-14T15:26:24.104Z"}}], "cna": {"metrics": [{"format": "CVSS", "cvssV3_1": {"scope": "CHANGED", "version": "3.1", "baseScore": 7.8, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "HIGH", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "cvssV4_0": {"version": "4.0", "baseScore": 7.3, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "userInteraction": "NONE", "attackComplexity": "HIGH", "attackRequirements": "PRESENT", "privilegesRequired": "LOW", "subIntegrityImpact": "NONE", "vulnIntegrityImpact": "HIGH", "subAvailabilityImpact": "NONE", "vulnAvailabilityImpact": "HIGH", "subConfidentialityImpact": "NONE", "vulnConfidentialityImpact": "HIGH"}, "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "affected": [{"vendor": "n/a", "product": "Intel(R) Core(TM) Ultra Processor stream cache mechanism", "versions": [{"status": "affected", "version": "See references"}], "defaultStatus": "unaffected"}], "references": [{"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01038.html", "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01038.html"}], "descriptions": [{"lang": "en", "value": "Improper isolation in the Intel(R) Core(TM) Ultra Processor stream cache mechanism may allow an authenticated user to potentially enable escalation of privilege via local access."}], "problemTypes": [{"descriptions": [{"lang": "en", "description": "escalation of privilege"}, {"lang": "en", "type": "CWE", "cweId": "CWE-1189", "description": "Improper isolation"}]}], "providerMetadata": {"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel", "dateUpdated": "2024-08-14T13:45:38.379Z"}}}, "cveMetadata": {"cveId": "CVE-2023-42667", "state": "PUBLISHED", "dateUpdated": "2024-08-22T03:55:12.553Z", "dateReserved": "2023-10-25T03:00:09.605Z", "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "datePublished": "2024-08-14T13:45:38.379Z", "assignerShortName": "intel"}, "dataVersion": "5.1"}