In the Linux kernel, the following vulnerability has been resolved:
scsi: storvsc: Fix handling of virtual Fibre Channel timeouts
Hyper-V provides the ability to connect Fibre Channel LUNs to the host
system and present them in a guest VM as a SCSI device. I/O to the vFC
device is handled by the storvsc driver. The storvsc driver includes a
partial integration with the FC transport implemented in the generic
portion of the Linux SCSI subsystem so that FC attributes can be displayed
in /sys. However, the partial integration means that some aspects of vFC
don't work properly. Unfortunately, a full and correct integration isn't
practical because of limitations in what Hyper-V provides to the guest.
In particular, in the context of Hyper-V storvsc, the FC transport timeout
function fc_eh_timed_out() causes a kernel panic because it can't find the
rport and dereferences a NULL pointer. The original patch that added the
call from storvsc_eh_timed_out() to fc_eh_timed_out() is faulty in this
regard.
In many cases a timeout is due to a transient condition, so the situation
can be improved by just continuing to wait like with other I/O requests
issued by storvsc, and avoiding the guaranteed panic. For a permanent
failure, continuing to wait may result in a hung thread instead of a panic,
which again may be better.
So fix the panic by removing the storvsc call to fc_eh_timed_out(). This
allows storvsc to keep waiting for a response. The change has been tested
by users who experienced a panic in fc_eh_timed_out() due to transient
timeouts, and it solves their problem.
In the future we may want to deprecate the vFC functionality in storvsc
since it can't be fully fixed. But it has current users for whom it is
working well enough, so it should probably stay for a while longer.
scsi: storvsc: Fix handling of virtual Fibre Channel timeouts
Hyper-V provides the ability to connect Fibre Channel LUNs to the host
system and present them in a guest VM as a SCSI device. I/O to the vFC
device is handled by the storvsc driver. The storvsc driver includes a
partial integration with the FC transport implemented in the generic
portion of the Linux SCSI subsystem so that FC attributes can be displayed
in /sys. However, the partial integration means that some aspects of vFC
don't work properly. Unfortunately, a full and correct integration isn't
practical because of limitations in what Hyper-V provides to the guest.
In particular, in the context of Hyper-V storvsc, the FC transport timeout
function fc_eh_timed_out() causes a kernel panic because it can't find the
rport and dereferences a NULL pointer. The original patch that added the
call from storvsc_eh_timed_out() to fc_eh_timed_out() is faulty in this
regard.
In many cases a timeout is due to a transient condition, so the situation
can be improved by just continuing to wait like with other I/O requests
issued by storvsc, and avoiding the guaranteed panic. For a permanent
failure, continuing to wait may result in a hung thread instead of a panic,
which again may be better.
So fix the panic by removing the storvsc call to fc_eh_timed_out(). This
allows storvsc to keep waiting for a response. The change has been tested
by users who experienced a panic in fc_eh_timed_out() due to transient
timeouts, and it solves their problem.
In the future we may want to deprecate the vFC functionality in storvsc
since it can't be fully fixed. But it has current users for whom it is
working well enough, so it should probably stay for a while longer.
Metrics
Affected Vendors & Products
Fixes
Solution
No solution given by the vendor.
Workaround
No workaround given by the vendor.
References
History
Mon, 15 Sep 2025 15:00:00 +0000
Type | Values Removed | Values Added |
---|---|---|
Description | In the Linux kernel, the following vulnerability has been resolved: scsi: storvsc: Fix handling of virtual Fibre Channel timeouts Hyper-V provides the ability to connect Fibre Channel LUNs to the host system and present them in a guest VM as a SCSI device. I/O to the vFC device is handled by the storvsc driver. The storvsc driver includes a partial integration with the FC transport implemented in the generic portion of the Linux SCSI subsystem so that FC attributes can be displayed in /sys. However, the partial integration means that some aspects of vFC don't work properly. Unfortunately, a full and correct integration isn't practical because of limitations in what Hyper-V provides to the guest. In particular, in the context of Hyper-V storvsc, the FC transport timeout function fc_eh_timed_out() causes a kernel panic because it can't find the rport and dereferences a NULL pointer. The original patch that added the call from storvsc_eh_timed_out() to fc_eh_timed_out() is faulty in this regard. In many cases a timeout is due to a transient condition, so the situation can be improved by just continuing to wait like with other I/O requests issued by storvsc, and avoiding the guaranteed panic. For a permanent failure, continuing to wait may result in a hung thread instead of a panic, which again may be better. So fix the panic by removing the storvsc call to fc_eh_timed_out(). This allows storvsc to keep waiting for a response. The change has been tested by users who experienced a panic in fc_eh_timed_out() due to transient timeouts, and it solves their problem. In the future we may want to deprecate the vFC functionality in storvsc since it can't be fully fixed. But it has current users for whom it is working well enough, so it should probably stay for a while longer. | |
Title | scsi: storvsc: Fix handling of virtual Fibre Channel timeouts | |
References |
|
|

Status: PUBLISHED
Assigner: Linux
Published:
Updated: 2025-09-15T14:46:14.280Z
Reserved: 2025-09-15T14:19:21.848Z
Link: CVE-2023-53245

No data.

Status : Awaiting Analysis
Published: 2025-09-15T15:15:51.683
Modified: 2025-09-15T15:22:27.090
Link: CVE-2023-53245

No data.

No data.