Description
An Improper Check for Unusual or Exceptional Conditions vulnerability in the chassis management daemon (chassisd) of Juniper Networks Junos OS allows an unauthenticated, network-based attacker to cause a
Denial-of-Service (DoS).
If an attempt is made to access specific sensors on platforms not supporting these sensors, either via GRPC or netconf, chassisd will crash and restart leading to a restart of all FPCs and thereby a complete outage.
This issue affects Junos OS:
* 21.4 versions from 21.4R3 before 21.4R3-S5,
* 22.1 versions from 22.1R3 before 22.1R3-S4,
* 22.2 versions from 22.2R2 before 22.2R3,
* 22.3 versions from 22.3R1 before 22.3R2-S2, 22.3R3,
* 22.4 versions from 22.4R1 before 22.4R2.
This issue does not affect Junos OS versions earlier than 21.4.
Denial-of-Service (DoS).
If an attempt is made to access specific sensors on platforms not supporting these sensors, either via GRPC or netconf, chassisd will crash and restart leading to a restart of all FPCs and thereby a complete outage.
This issue affects Junos OS:
* 21.4 versions from 21.4R3 before 21.4R3-S5,
* 22.1 versions from 22.1R3 before 22.1R3-S4,
* 22.2 versions from 22.2R2 before 22.2R3,
* 22.3 versions from 22.3R1 before 22.3R2-S2, 22.3R3,
* 22.4 versions from 22.4R1 before 22.4R2.
This issue does not affect Junos OS versions earlier than 21.4.
No analysis available yet.
Remediation
Vendor Solution
The following software releases have been updated to resolve this specific issue: 21.4R3-S5, 22.1R3-S4, 22.2R3, 22.3R2-S2, 22.3R3, 22.4R2, 23.2R1, and all subsequent releases.
Vendor Workaround
There are no known workarounds for this issue.
Tracking
Sign in to view the affected projects.
Advisories
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2024-38056 | An Improper Check for Unusual or Exceptional Conditions vulnerability in the chassis management daemon (chassisd) of Juniper Networks Junos OS allows an unauthenticated, network-based attacker to cause a Denial-of-Service (DoS). If an attempt is made to access specific sensors on platforms not supporting these sensors, either via GRPC or netconf, chassisd will crash and restart leading to a restart of all FPCs and thereby a complete outage. This issue affects Junos OS: * 21.4 versions from 21.4R3 before 21.4R3-S5, * 22.1 versions from 22.1R3 before 22.1R3-S4, * 22.2 versions from 22.2R2 before 22.2R3, * 22.3 versions from 22.3R1 before 22.3R2-S2, 22.3R3, * 22.4 versions from 22.4R1 before 22.4R2. This issue does not affect Junos OS versions earlier than 21.4. |
References
| Link | Providers |
|---|---|
| https://supportportal.juniper.net/JSA82989 |
|
History
Mon, 23 Sep 2024 14:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Juniper junos
|
|
| CPEs | cpe:2.3:o:juniper:junos:21.1:r3-s1:*:*:*:*:*:* cpe:2.3:o:juniper:junos:21.1:r3-s2:*:*:*:*:*:* cpe:2.3:o:juniper:junos:21.1:r3-s3:*:*:*:*:*:* cpe:2.3:o:juniper:junos:21.1:r3:*:*:*:*:*:* cpe:2.3:o:juniper:junos:21.4:r3-s1:*:*:*:*:*:* cpe:2.3:o:juniper:junos:21.4:r3-s2:*:*:*:*:*:* cpe:2.3:o:juniper:junos:21.4:r3-s3:*:*:*:*:*:* cpe:2.3:o:juniper:junos:21.4:r3-s4:*:*:*:*:*:* cpe:2.3:o:juniper:junos:21.4:r3:*:*:*:*:*:* cpe:2.3:o:juniper:junos:22.2:r2-s1:*:*:*:*:*:* cpe:2.3:o:juniper:junos:22.2:r2-s2:*:*:*:*:*:* cpe:2.3:o:juniper:junos:22.2:r2:*:*:*:*:*:* cpe:2.3:o:juniper:junos:22.3:r1-s1:*:*:*:*:*:* cpe:2.3:o:juniper:junos:22.3:r1-s2:*:*:*:*:*:* cpe:2.3:o:juniper:junos:22.3:r1:*:*:*:*:*:* cpe:2.3:o:juniper:junos:22.3:r2-s1:*:*:*:*:*:* cpe:2.3:o:juniper:junos:22.3:r2:*:*:*:*:*:* cpe:2.3:o:juniper:junos:22.4:r1-s1:*:*:*:*:*:* cpe:2.3:o:juniper:junos:22.4:r1-s2:*:*:*:*:*:* cpe:2.3:o:juniper:junos:22.4:r1:*:*:*:*:*:* |
|
| Vendors & Products |
Juniper junos
|
Status: PUBLISHED
Assigner: juniper
Published:
Updated: 2024-08-02T04:26:15.620Z
Reserved: 2024-06-25T15:12:53.240Z
Link: CVE-2024-39530
Updated: 2024-07-11T20:29:33.280Z
Status : Modified
Published: 2024-07-11T16:15:04.613
Modified: 2024-11-21T09:27:56.513
Link: CVE-2024-39530
No data.
OpenCVE Enrichment
No data.
Weaknesses
EUVD