Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
Metrics
Affected Vendors & Products
References
History
Thu, 09 Jan 2025 15:15:00 +0000
Type | Values Removed | Values Added |
---|---|---|
Metrics |
cvssV3_1
|
Thu, 09 Jan 2025 08:15:00 +0000
Type | Values Removed | Values Added |
---|---|---|
Description | Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). | |
Title | Authenticated command injection via <redacted>.exe <redacted> parameter | |
Weaknesses | CWE-250 CWE-78 |
|
References |
| |
Metrics |
cvssV4_0
|
MITRE
Status: PUBLISHED
Assigner: DIVD
Published: 2025-01-09T07:56:46.982Z
Updated: 2025-01-09T14:36:23.194Z
Reserved: 2024-08-14T09:27:41.767Z
Link: CVE-2024-43649
Vulnrichment
Updated: 2025-01-09T14:36:16.749Z
NVD
Status : Received
Published: 2025-01-09T08:15:27.233
Modified: 2025-01-09T15:15:16.173
Link: CVE-2024-43649
Redhat
No data.