Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Default Permissions
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Cognex | In-Sight 2000 series | unaffected |
|
||||||
| Cognex | In-Sight 7000 series | unaffected |
|
||||||
| Cognex | In-Sight 8000 series | unaffected |
|
||||||
| Cognex | In-Sight 9000 series | unaffected |
|
||||||
| Cognex | In-Sight Explorer | unaffected |
|
No data.
No data.
| Vendor | Product | Versions |
|---|---|---|
| Cognex | In-sight Camera Firmware | — |
| Cognex | In-sight Explorer | — |
| Microsoft | Windows | — |
Vendor Workaround
Cognex reports that In-Sight Explorer based vision systems are legacy products not intended for new applications. To reduce risk, asset owners are advised to switch to next generation In-Sight Vision Suite based vision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 series embedded cameras.
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2025-30189 | A local attacker with low privileges on the Windows system where the software is installed can exploit this vulnerability to corrupt sensitive data. A data folder is created with very weak privileges, allowing any user logged into the Windows system to modify its content. |
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.113% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Cognex
Cognex in-sight Camera Firmware Cognex in-sight Explorer Microsoft Microsoft windows |
|
| Vendors & Products |
Cognex
Cognex in-sight Camera Firmware Cognex in-sight Explorer Microsoft Microsoft windows |
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A local attacker with low privileges on the Windows system where the software is installed can exploit this vulnerability to corrupt sensitive data. A data folder is created with very weak privileges, allowing any user logged into the Windows system to modify its content. | |
| Title | Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Default Permissions | |
| Weaknesses | CWE-276 | |
| References |
| |
| Metrics |
cvssV3_1
|
Incorrect Default Permissions