General Industrial Controls Lynx+ Gateway is vulnerable to a weak password requirement vulnerability, which may
allow an attacker to execute a brute-force attack resulting in
unauthorized access and login.
Advisories

No advisories yet.

Fixes

Solution

No solution given by the vendor.


Workaround

General Industrial Controls (GIC) did not respond to CISA's attempts to coordinate. Users of General Industrial Controls Lynx+ Gateway are encouraged to reach out to GIC for more information.

History

Fri, 14 Nov 2025 23:30:00 +0000

Type Values Removed Values Added
Description General Industrial Controls Lynx+ Gateway is vulnerable to a weak password requirement vulnerability, which may allow an attacker to execute a brute-force attack resulting in unauthorized access and login.
Title General Industrial Controls Lynx+ Gateway Weak Password Requirements
Weaknesses CWE-521
References
Metrics cvssV3_1

{'score': 8.2, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N'}

cvssV4_0

{'score': 8.8, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N'}