A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe API, processed by the sub_423930 function in /usr/bin/webmgnt. The phy_interface parameter is not sanitized, allowing attackers to inject arbitrary commands via a POST request to /cgi-bin/mbox-config?method=SET&section=multi_pppoe. When the action parameter is set to "one_click_redial", the unsanitized phy_interface is used in a system() call, enabling execution of malicious commands. This can lead to unauthorized access to sensitive files, execution of arbitrary code, or full device compromise.
Advisories
Source ID Title
EUVD EUVD EUVD-2025-30197 A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe API, processed by the sub_423930 function in /usr/bin/webmgnt. The phy_interface parameter is not sanitized, allowing attackers to inject arbitrary commands via a POST request to /cgi-bin/mbox-config?method=SET&section=multi_pppoe. When the action parameter is set to "one_click_redial", the unsanitized phy_interface is used in a system() call, enabling execution of malicious commands. This can lead to unauthorized access to sensitive files, execution of arbitrary code, or full device compromise.
Fixes

Solution

No solution given by the vendor.


Workaround

No workaround given by the vendor.

History

Fri, 03 Oct 2025 17:30:00 +0000

Type Values Removed Values Added
First Time appeared Comfast cf-xr11 Firmware
CPEs cpe:2.3:h:comfast:cf-xr11:-:*:*:*:*:*:*:*
cpe:2.3:o:comfast:cf-xr11_firmware:2.7.2:*:*:*:*:*:*:*
Vendors & Products Comfast cf-xr11 Firmware

Fri, 19 Sep 2025 14:15:00 +0000

Type Values Removed Values Added
Weaknesses CWE-77
Metrics cvssV3_1

{'score': 8.8, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H'}

ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'poc', 'Technical Impact': 'total'}, 'version': '2.0.3'}


Fri, 19 Sep 2025 09:45:00 +0000

Type Values Removed Values Added
First Time appeared Comfast
Comfast cf-xr11
Vendors & Products Comfast
Comfast cf-xr11

Thu, 18 Sep 2025 21:00:00 +0000

Type Values Removed Values Added
Description A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe API, processed by the sub_423930 function in /usr/bin/webmgnt. The phy_interface parameter is not sanitized, allowing attackers to inject arbitrary commands via a POST request to /cgi-bin/mbox-config?method=SET&section=multi_pppoe. When the action parameter is set to "one_click_redial", the unsanitized phy_interface is used in a system() call, enabling execution of malicious commands. This can lead to unauthorized access to sensitive files, execution of arbitrary code, or full device compromise.
References

cve-icon MITRE

Status: PUBLISHED

Assigner: mitre

Published:

Updated: 2025-09-19T14:08:26.011Z

Reserved: 2025-08-17T00:00:00.000Z

Link: CVE-2025-57293

cve-icon Vulnrichment

Updated: 2025-09-19T14:07:41.587Z

cve-icon NVD

Status : Analyzed

Published: 2025-09-18T21:15:49.203

Modified: 2025-10-03T17:24:46.327

Link: CVE-2025-57293

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

Updated: 2025-09-19T09:36:22Z