Metrics
Affected Vendors & Products
Tue, 02 Sep 2025 18:15:00 +0000
Type | Values Removed | Values Added |
---|---|---|
First Time appeared |
Linksys re6250 Firmware
Linksys re6300 Firmware Linksys re6350 Firmware Linksys re6500 Firmware Linksys re7000 Firmware Linksys re9000 Firmware |
|
CPEs | cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:* cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:* cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:* cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:* cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:* cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:* cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:* cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:* cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:* cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:* cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:* cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:* |
|
Vendors & Products |
Linksys re6250 Firmware
Linksys re6300 Firmware Linksys re6350 Firmware Linksys re6500 Firmware Linksys re7000 Firmware Linksys re9000 Firmware |
Wed, 27 Aug 2025 11:30:00 +0000
Type | Values Removed | Values Added |
---|---|---|
First Time appeared |
Linksys
Linksys re6250 Linksys re6300 Linksys re6350 Linksys re6500 Linksys re7000 Linksys re9000 |
|
Vendors & Products |
Linksys
Linksys re6250 Linksys re6300 Linksys re6350 Linksys re6500 Linksys re7000 Linksys re9000 |
Tue, 26 Aug 2025 15:15:00 +0000
Type | Values Removed | Values Added |
---|---|---|
Metrics |
ssvc
|
Tue, 26 Aug 2025 14:15:00 +0000
Type | Values Removed | Values Added |
---|---|---|
Description | A flaw has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function singlePortForwardAdd of the file /goform/singlePortForwardAdd. This manipulation of the argument ruleName/schedule/inboundFilter causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | |
Title | Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 singlePortForwardAdd stack-based overflow | |
Weaknesses | CWE-119 CWE-121 |
|
References |
| |
Metrics |
cvssV2_0
|

Status: PUBLISHED
Assigner: VulDB
Published:
Updated: 2025-08-26T15:01:59.378Z
Reserved: 2025-08-26T07:35:50.516Z
Link: CVE-2025-9483

Updated: 2025-08-26T15:01:45.635Z

Status : Analyzed
Published: 2025-08-26T14:15:47.887
Modified: 2025-09-02T18:08:02.610
Link: CVE-2025-9483

No data.

Updated: 2025-08-27T11:21:41Z