CVE-2026-100374

Missing user buffer validation in SMBus block read and block process call syscalls allows kernel memory writes

Published Nov 23, 2026 CVSS 3.1 · 7.8 High EPSS n/a KEV · Not listed
Description
The system call verification handlers for smbus_block_read() and smbus_block_pcall() in drivers/smbus/smbus_handlers.c (z_vrfy_smbus_block_read() and z_vrfy_smbus_block_pcall()) validated the device object, the count pointers and (for process call) the send buffer, but never validated the receive buffer (buf / rcv_buf). The call then proceeds into the driver implementation, which runs in supervisor mode and writes the bytes received from the SMBus peripheral through that pointer.

A user-mode thread on a system built with CONFIG_USERSPACE that has been granted access to an SMBus device object can pass an arbitrary address, including kernel data or another thread's memory, as the receive buffer. The driver then writes up to SMBUS_BLOCK_BYTES_MAX (32) bytes of peripheral-supplied data there (the STM32 driver writes as many bytes as the peripheral's length byte announces, up to 255). The address is fully attacker-chosen; the written content comes from the bus and is typically influenceable by the caller through the choice of peripheral and command, or by first writing data to a device that echoes it back.

This breaks the user/kernel isolation boundary: it gives an unprivileged thread a kernel-memory write primitive usable for privilege escalation, or at minimum to corrupt kernel state or crash the system. The fix adds K_SYSCALL_MEMORY_WRITE() checks of the receive buffer for the documented worst case, SMBUS_BLOCK_BYTES_MAX. Systems without CONFIG_USERSPACE are not affected.

Analysis

No analysis available yet

Remediation

No remediation available yet

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Description The system call verification handlers for smbus_block_read() and smbus_block_pcall() in drivers/smbus/smbus_handlers.c (z_vrfy_smbus_block_read() and z_vrfy_smbus_block_pcall()) validated the device object, the count pointers and (for process call) the send buffer, but never validated the receive buffer (buf / rcv_buf). The call then proceeds into the driver implementation, which runs in supervisor mode and writes the bytes received from the SMBus peripheral through that pointer. A user-mode thread on a system built with CONFIG_USERSPACE that has been granted access to an SMBus device object can pass an arbitrary address, including kernel data or another thread's memory, as the receive buffer. The driver then writes up to SMBUS_BLOCK_BYTES_MAX (32) bytes of peripheral-supplied data there (the STM32 driver writes as many bytes as the peripheral's length byte announces, up to 255). The address is fully attacker-chosen; the written content comes from the bus and is typically influenceable by the caller through the choice of peripheral and command, or by first writing data to a device that echoes it back. This breaks the user/kernel isolation boundary: it gives an unprivileged thread a kernel-memory write primitive usable for privilege escalation, or at minimum to corrupt kernel state or crash the system. The fix adds K_SYSCALL_MEMORY_WRITE() checks of the receive buffer for the documented worst case, SMBUS_BLOCK_BYTES_MAX. Systems without CONFIG_USERSPACE are not affected.
Title Missing user buffer validation in SMBus block read and block process call syscalls allows kernel memory writes
Weaknesses CWE-822
References
Metrics cvssV3_1

{'score': 7.8, 'vector': 'CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H'}

Subscriptions

No data.

Weaknesses
  • CWE-822

    Untrusted Pointer Dereference

Sources

Status
PUBLISHED
Assigner
zephyr
Published
Updated
Nov 23, 2026, 6:02 PM
Reserved
Sep 25, 2026, 7:26 PM

No data.