CVE-2026-102255

Published Oct 7, 2026 CVSS 3.1 · 10 Critical EPSS < 1% KEV · Not listed
Description
A Pre-authentication SSRF vulnerability exists in the SMA1000 Appliance Work Place interface due to an unintended alternate access path. By abusing this path, a remote unauthenticated attacker could potentially exploit this vulnerability to direct the appliance to issue requests on their behalf and reach internal functionality and perform unauthorized operations.

Analysis

AI-generated

Technical impact

A pre‑authentication Server‑Side Request Forgery flaw in SonicWall’s SMA1000 Appliance Work Place interface allows a remote attacker to exploit an unintended alternate access path. By directing the appliance to issue HTTP requests on the attacker’s behalf, the attacker can reach internal services, read sensitive data or trigger unauthorized operations that the device is permitted to perform. Because no authentication is required, the vulnerability exposes the network to potential confidentiality, integrity or availability risks, depending on which internal resources are accessed.

Affected Systems

The affected product is the SonicWall SMA1000 Appliance. Any instance that runs the Work Place interface with the alternate access path is vulnerable. No explicit version range is listed, so provisioning a patch requires checking the current firmware against SonicWall’s advisory for this specific issue.

Risk and Exploitability

The exploit path is remote and unauthenticated, meaning that an attacker who can reach the Work Place interface can configure the appliance to send requests to arbitrary internal targets. The EPSS score is not available, but the absence of a KEV listing suggests the vulnerability has not yet been widely exploited. Nevertheless, the lack of authentication and the broad capability of SSRF create a high risk scenario; security teams should assume a high likelihood of exploitation until a vendor fix is applied. The CVSS score of 10.0 confirms maximum severity.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Apply the latest SonicWall firmware update that resolves the SSRF vulnerability.
  • Limit inbound traffic to the SMA1000 Work Place interface to a restricted set of trusted IP addresses or management networks.
  • If possible, disable the alternate access path or the Work Place interface when it is not required for business operations.

Generated by OpenCVE AI on October 7, 2026 at 18:45 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'yes', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
Title Remote unauthenticated SSRF in SonicWall SMA1000 Work Place interface
Type Values Removed Values Added
Metrics cvssV3_1

{'score': 10.0, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H'}

Type Values Removed Values Added
Title Remote unauthenticated SSRF in SonicWall SMA1000 Work Place interface
Type Values Removed Values Added
First Time appeared Sonicwall
Sonicwall sma1000
Vendors & Products Sonicwall
Sonicwall sma1000
Type Values Removed Values Added
Description A Pre-authentication SSRF vulnerability exists in the SMA1000 Appliance Work Place interface due to an unintended alternate access path. By abusing this path, a remote unauthenticated attacker could potentially exploit this vulnerability to direct the appliance to issue requests on their behalf and reach internal functionality and perform unauthorized operations.
Weaknesses CWE-441
CWE-918
References
Weaknesses
  • CWE-441

    Unintended Proxy or Intermediary ('Confused Deputy')

  • CWE-918

    Server-Side Request Forgery (SSRF)

Sources

Status
PUBLISHED
Assigner
sonicwall
Published
Updated
Oct 7, 2026, 3:51 PM
Reserved
Sep 28, 2026, 7:39 PM
Status
Awaiting Analysis
Published
Oct 7, 2026, 1:17 PM
Modified
Oct 7, 2026, 4:17 PM