CVE-2026-10756

Published Oct 27, 2026 CVSS 4.0 · 7.7 High EPSS < 1% KEV · Not listed
Description
TRO600 contains a vulnerability that allows an authenticated attacker to bypass network access restrictions and access services intended to be reachable only from localhost. By leveraging port forwarding, an attacker can interact with locally bound ports and services, resulting in unauthorized access to sensitive functionality and confidential information, and causing availability impact.

Analysis

AI-generated

Technical impact

The vulnerability in Hitachi Energy TRO600 firmware lets an authenticated user bypass network access controls, allowing connection to services that are meant to be reachable only from the local machine. By configuring port forwarding, the attacker can interact with locally bound ports, gaining unauthorized access to sensitive functions and confidential data, which also leads to availability issues.

Affected Systems

Devices running Hitachi Energy TRO600 Series firmware are affected. No specific firmware version is listed in the advisory, so all versions of the series should be considered vulnerable until a patch is applied.

Risk and Exploitability

The CVSS score of 7.7 indicates a high severity for this flaw. The EPSS score is not available, and the vulnerability is not listed in the CISA KEV catalog. The attack requires an authenticated user credential and the ability to enable port forwarding, implying that the attacker must first compromise or obtain legitimate access to the device. Once authenticated, the attacker can exploit the flaw to reach privileged services, exposing sensitive data and potentially disrupting device operations.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Upgrade the device to the latest TRO600 firmware released by Hitachi Energy that contains the fix for this vulnerability.
  • Enforce strong, unique credentials for the device administrator account and limit its use to authorized personnel only.
  • Configure the device firewall to block incoming connections to localhost‑only ports and disable unnecessary port forwarding features.

Generated by OpenCVE AI on October 27, 2026 at 13:22 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
First Time appeared Hitachienergy
Hitachienergy tro600 Firmware
Vendors & Products Hitachienergy
Hitachienergy tro600 Firmware
Type Values Removed Values Added
Description TRO600 contains a vulnerability that allows an authenticated attacker to bypass network access restrictions and access services intended to be reachable only from localhost. By leveraging port forwarding, an attacker can interact with locally bound ports and services, resulting in unauthorized access to sensitive functionality and confidential information, and causing availability impact.
Weaknesses CWE-923
References
Metrics cvssV4_0

{'score': 7.7, 'vector': 'CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N'}

Weaknesses
  • CWE-923

    Improper Restriction of Communication Channel to Intended Endpoints

Sources

Status
PUBLISHED
Assigner
Hitachi Energy
Published
Updated
Nov 4, 2026, 4:50 PM
Reserved
Jun 3, 2026, 2:37 PM
Status
Deferred
Published
Oct 27, 2026, 12:17 PM
Modified
Nov 4, 2026, 5:17 PM