Technical impact
An attacker can send a crafted SIP MESSAGE to an affected FreeSWITCH instance, using a plus sign in the To user field to select the "api" chat protocol. The parser then hands the string to the switch API executor, allowing execution of arbitrary FreeSWITCH API commands, which in turn may operating‑system commands with full daemon privileges. This vulnerability arises from improper handling of user input (CWE-749), command injection (CWE-77), and OS command execution (CWE-78). This flaw grants configuration disclosure, arbitrary call control, and remote code execution on the host running the daemon.
Affected Systems
The vulnerability exists in all releases of SignalWire FreeSWITCH prior to version 1.11.3. Any instance that has inbound SIP MESSAGE handling enabled on its stock internal or external profiles and accepts authenticated accounts—especially those with directory users lacking password protections—can be exploited.
Risk and Exploitability
The CVSS score of 9.8 marks the issue as an extremely high‑severity remote code execution vulnerability. Although the EPSS score is 44% and the flaw is now listed in the CISA KEV catalog, alerts indicate that exploitation has been observed in the wild. The likely attack vector is a remote SIP MESSAGE sent to the FreeSWITCH server, which can be delivered over untrusted networks once inbound messaging is enabled while authentication is weak or missing.