CVE-2026-118607

Alpine iLX-F511 diagapp Command Injection Vulnerability

Published Oct 28, 2026 CVSS 3.0 · 6.8 Medium EPSS < 1% KEV · Not listed
Description
Alpine iLX-F511 diagapp Command Injection Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Alpine iLX-F511 devices. Authentication is not required to exploit this vulnerability.

The specific flaw exists within the diagapp component. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-28750.

Analysis

AI-generated

Technical impact

The vulnerability resides in the diagapp component of Alpine iLX‑F511 devices and permits a command injection flaw that happens because a user‑supplied string is not properly validated before it is passed to a system call. An attacker who gains local, physical access to the device can exploit this flaw to run arbitrary commands with root privileges, enabling full compromise of the device's confidentiality, integrity, and availability.

Affected Systems

All installations of the Alpine iLX‑F511 device are affected, regardless of firmware version, as no specific version remediation information is listed. The diagapp component is the sole entry point for the vulnerability.

Risk and Exploitability

With a CVSS score of 6.8 the risk is moderate, and the EPSS score is currently unavailable. The vulnerability is not present in the CISA KEV catalog. Attackers require physical presence to interact with the diagapp interface; no authentication is needed. Once accessed, the attack can execute system commands directly as root, allowing full control of the device.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Check for and install any vendor‑issued firmware or configuration updates that address the diagapp command injection flaw.
  • If a patch is not yet available, disable the diagapp service or remove it from the device configuration to prevent exploitation.
  • Implement strict physical access controls and lock‑down procedures so that only authorized personnel can reach the device’s console and interfaces.
  • Configure network segmentation and monitoring to detect any anomalous command execution or unauthorized access attempts on the device.

Generated by OpenCVE AI on October 28, 2026 at 18:42 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
First Time appeared Alpine
Alpine ilx-f511
Vendors & Products Alpine
Alpine ilx-f511
Type Values Removed Values Added
Description Alpine iLX-F511 diagapp Command Injection Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Alpine iLX-F511 devices. Authentication is not required to exploit this vulnerability. The specific flaw exists within the diagapp component. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-28750.
Title Alpine iLX-F511 diagapp Command Injection Vulnerability
Weaknesses CWE-78
References
Metrics cvssV3_0

{'score': 6.8, 'vector': 'CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H'}

Weaknesses
  • CWE-78

    Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

Sources

Status
PUBLISHED
Assigner
zdi
Published
Updated
Nov 5, 2026, 5:14 PM
Reserved
Oct 28, 2026, 4:49 PM
Status
Deferred
Published
Oct 28, 2026, 5:18 PM
Modified
Nov 5, 2026, 5:17 PM