CVE-2026-119569

Parse Server 9.0.0 before 9.10.5-alpha.9 Prototype Pollution Denial of Service

Published Oct 30, 2026 CVSS 4.0 · 6 Medium EPSS < 1% KEV · Not listed
Description
Parse Server before 8.6.108 and 9.0.0 before 9.10.5-alpha.9 contains a prototype pollution vulnerability because user-controlled keys are expanded into objects without own-property checks. Clients with class write access can send dot notation field keys or ACL entry names matching built-in object members to corrupt built-in functions, causing all requests to fail until server restart.

Analysis

AI-generated

Technical impact

Parse Server uses user-controlled keys without own-property checks, enabling prototype pollution. Attackers with class write permissions can craft dot notation field keys or ACL names that overwrite built-in object members. This corrupts internal functions, causing every server request to fail until a restart, resulting in denial of service.

Affected Systems

Parse Server by the parse-community, versions 8.x prior to 8.6.108 and 9.x before 9.10.5-alpha.9 are affected.

Risk and Exploitability

The CVSS score of 6 indicates moderate severity. EPSS is not available, and the vulnerability is not listed in CISA KEV. Exploitation requires an attacker who controls a client with write class access to inject malicious field keys or ACL names. Such an attacker can trigger the prototype pollution, corrupting server behavior until a restart.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Upgrade Parse Server to version 9.10.5-alpha.9 or later to apply the prototype pollution fix.
  • Revoke or restrict write class permissions that allow dot notation field keys or ACL names matching built-in properties.
  • Restart the server after applying the patch to clear corrupted prototypes and prevent further denial of service attempts.

Generated by OpenCVE AI on October 30, 2026 at 14:22 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
First Time appeared Parse Community
Parse Community parse Server
Vendors & Products Parse Community
Parse Community parse Server
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description Parse Server before 8.6.108 and 9.0.0 before 9.10.5-alpha.9 contains a prototype pollution vulnerability because user-controlled keys are expanded into objects without own-property checks. Clients with class write access can send dot notation field keys or ACL entry names matching built-in object members to corrupt built-in functions, causing all requests to fail until server restart.
Title Parse Server 9.0.0 before 9.10.5-alpha.9 Prototype Pollution Denial of Service
First Time appeared Parseplatform
Parseplatform parse-server
Weaknesses CWE-1321
CPEs cpe:2.3:a:parseplatform:parse-server:*:*:*:*:*:*:*:*
Vendors & Products Parseplatform
Parseplatform parse-server
References
Metrics cvssV3_1

{'score': 5.3, 'vector': 'CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H'}

cvssV4_0

{'score': 6, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N'}

Weaknesses
  • CWE-1321

    Improperly Controlled Modification of Object Prototype Attributes ('Prototype Pollution')

Sources

Status
PUBLISHED
Assigner
VulnCheck
Published
Updated
Oct 30, 2026, 3:53 PM
Reserved
Oct 30, 2026, 10:56 AM
Status
Awaiting Analysis
Published
Oct 30, 2026, 2:16 PM
Modified
Oct 30, 2026, 4:17 PM