Description
A vulnerability was determined in Tenda AC19 16.03.10.07. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. This manipulation of the argument deviceId causes heap-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.
Published: 2026-11-07
Score: 10 Critical
EPSS: n/a
KEV: No
Impact: Heap-Based Buffer Overflow
Action: Immediate Patch
AI Analysis

Impact

The CVE describes a heap-based buffer overflow in the saveParentControlInfo function exposed through the /goform/saveParentControlInfo endpoint on the Tenda AC19 firmware. By manipulating the deviceId argument, an attacker can corrupt data stored on the heap during a remote request. The description explicitly notes that the overflow may be exploited, but it does not specify the exact consequences such as code execution or denial of service, so the impact should be reported only as a memory corruption vulnerability.

Affected Systems

The vulnerability affects the Tenda AC19 router with firmware version 16.03.10.07. No other products or versions are mentioned in the provided data.

Risk and Exploitability

The CVSS score is 10, indicating critical severity. No EPSS data is available, and the issue is not listed in the CISA KEV catalog, but the fact that it can be triggered remotely and is publicly disclosed implies a high likelihood that an attacker with modest technical skill could attempt to exploit it. The risk is therefore considered high, though the exact exploitation outcome is undefined in the vendor statement.

Generated by OpenCVE AI on November 7, 2026 at 15:54 UTC.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Upgrade the router firmware to the latest version that includes the buffer overflow patch
  • If a firmware update is not yet available, block external access to the /goform/saveParentControlInfo endpoint using the device’s firewall or a network perimeter device
  • Monitor network traffic for anomalous requests to the /goform/saveParentControlInfo endpoint and investigate any such incidents promptly

Generated by OpenCVE AI on November 7, 2026 at 15:54 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories yet.

History

Sat, 07 Nov 2026 14:00:00 +0000

Type Values Removed Values Added
Description A vulnerability was determined in Tenda AC19 16.03.10.07. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. This manipulation of the argument deviceId causes heap-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.
Title Tenda AC19 saveParentControlInfo heap-based overflow
First Time appeared Tenda
Tenda ac19
Weaknesses CWE-119
CWE-122
CPEs cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*
Vendors & Products Tenda
Tenda ac19
References
Metrics cvssV2_0

{'score': 10, 'vector': 'AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:C'}

cvssV3_0

{'score': 10, 'vector': 'CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C'}

cvssV3_1

{'score': 10, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C'}

cvssV4_0

{'score': 10, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P'}


cve-icon MITRE

Status: PUBLISHED

Assigner: VulDB

Published:

Updated: 2026-11-07T13:45:19.423Z

Reserved: 2026-11-06T17:16:21.436Z

Link: CVE-2026-123966

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Deferred

Published: 2026-11-07T14:17:01.800

Modified: 2026-11-07T14:17:01.973

Link: CVE-2026-123966

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

Updated: 2026-11-07T16:00:17Z

Weaknesses
  • CWE-119

    Improper Restriction of Operations within the Bounds of a Memory Buffer

  • CWE-122