CVE-2026-133846

FlowIntel Missing Authorization Check Allows Unauthorized Revival of Completed Privileged Cases via Task Reopening

Published Nov 20, 2026 CVSS 4.0 · 5.3 Medium EPSS n/a KEV · Not listed
Description
FlowIntel contains an authorization bypass in its task management workflow. When a user reopens a completed task (by toggling its completion state or changing its status to a non-finished value) or creates a new task within a completed privileged case, the parent case is automatically revived (un-completed, status reset to Created, finish date cleared). The system failed to enforce the required Admin or Case Admin privilege check before performing this case revival side effect.

A user with basic task-level permissions (e.g., editor, queuer, or queue admin) could trigger the revival of a completed privileged case through the browser interface or the REST API, without holding the elevated role required for case-level operations. This could disrupt case lifecycle management, clear completion metadata, and potentially expose the case to further unauthorized modifications.

The vulnerability affects both the browser-based task completion/status-change endpoints and the corresponding API endpoints, as well as the task creation flow.

Affected versions: FlowIntel prior to 4.1.0.

Analysis

No analysis available yet

Remediation

Vendor Solution

The fix introduces explicit authorization checks (can_reopen_case and can_reopen_task) that require Admin or Case Admin privileges before a completed privileged case can be revived as a side effect of task reopening or task creation. Denial is enforced at the core model layer and at both the browser and API endpoint layers, with audit logging of denied attempts. Legitimate task creation is preserved, but the automatic case revival is suppressed for unauthorized users.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Description FlowIntel contains an authorization bypass in its task management workflow. When a user reopens a completed task (by toggling its completion state or changing its status to a non-finished value) or creates a new task within a completed privileged case, the parent case is automatically revived (un-completed, status reset to Created, finish date cleared). The system failed to enforce the required Admin or Case Admin privilege check before performing this case revival side effect. A user with basic task-level permissions (e.g., editor, queuer, or queue admin) could trigger the revival of a completed privileged case through the browser interface or the REST API, without holding the elevated role required for case-level operations. This could disrupt case lifecycle management, clear completion metadata, and potentially expose the case to further unauthorized modifications. The vulnerability affects both the browser-based task completion/status-change endpoints and the corresponding API endpoints, as well as the task creation flow. Affected versions: FlowIntel prior to 4.1.0.
Title FlowIntel Missing Authorization Check Allows Unauthorized Revival of Completed Privileged Cases via Task Reopening
First Time appeared Flowintel
Flowintel flowintel
Weaknesses CWE-862
CPEs cpe:2.3:a:flowintel:flowintel:*:*:*:*:*:*:*:*
Vendors & Products Flowintel
Flowintel flowintel
References
Metrics cvssV4_0

{'score': 5.3, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
CIRCL
Published
Updated
Nov 20, 2026, 2:38 PM
Reserved
Nov 20, 2026, 2:38 PM

No data.