Description
IBM Power Systems Firmware FW1060.00 through FW1060.81, OP940.00 through OP940.A2, OP910.00 through OP910.95, and OP940.00 through OP940.82 could allow a remote attacker to cause a denial of service due to improper validation of input length.
Published: 2026-11-08
Score: 6.5 Medium
EPSS: n/a
KEV: No
Impact: Denial of Service
Action: Patch firmware
AI Analysis

Impact

This vulnerability permits a remote attacker to cause a denial of service in IBM Power Systems firmware because input length is improperly validated. The flaw can be triggered by sending a deliberately malformed command to the Baseboard Management Controller (BMC). If successfully exploited, the affected device may become unresponsive, requiring a reboot or manual intervention, thereby disrupting availability of the host and any dependent services. The weakness falls under CWE-617.

Affected Systems

IBM Power Systems employing OpenBMC firmware versions FW1060.00 through FW1060.81, OP940.00 through OP940.A2, OP910.00 through OP910.95, and OP940.00 through OP940.82 are affected. The firmware is used in Power 10 models such as the IBM Power System S1022, S1024, S1022s, S1014, L1022, L1024, E1050, and S1012, as well as the OpenPower 9 AC922 series. IBM Power Hardware Management Console devices running firmware until OP940.82 also remain vulnerable.

Risk and Exploitability

The vulnerability carries a CVSS score of 6.5, indicating medium severity, while the exploitation probability is not published and the issue is not listed in the CISA KEV database. The attack vector is remote, relying on network access to the BMC. Although the flaw can only induce a service interruption, it may still impact critical workloads and require downtime to restore service. No elevated privileges or persistence are required; the attack can be launched from an external host with network reach to the management interface.

Generated by OpenCVE AI on November 8, 2026 at 21:21 UTC.

Remediation

Vendor Solution

Customers with the products below should install FW1060.82(1060_199) or newer to remediate this vulnerability. Power 10 1) IBM Power System S1022 (9105-22A) 2) IBM Power System S1024 (9105-42A) 3) IBM Power System S1022s (9105-22B) 4) IBM Power System S1014 (9105-41B) 5) IBM Power System L1022 (9786-22H) 6) IBM Power System L1024 (9786-42H) 7) IBM Power System E1050 (9043-MRX) 8) IBM Power System S1012 (9028-21B) Customers with the products below should install OP940.A3, OP910.96 or newer to remediate this vulnerability. OpenPower 9 1) IBM Power System AC922 (8335-GTG) 2) IBM Power System AC922 (8335-GTC, 8335-GTW) 3) IBM Power System AC922 (8335-GTH, 8335-GTX) Customers with the products below should install OP940.83 or newer to remediate this vulnerability. 1) IBM Power Hardware Management Console (7063-CR2) The images mentioned above can be located at IBM Fix Central :  https://www.ibm.com/support/fixcentral/


Vendor Workaround

Protect access to the BMC's network interface by operating it on a private network or behind a firewall.


OpenCVE Recommended Actions

  • Update IBM Power Systems firmware to FW1060.82(1060_199) or newer for Power 10 models, to OP940.A3, OP910.96, or newer for Power 10 models, or to OP940.83 or newer for Power Hardware Management Console.
  • If an immediate firmware update is not possible, restrict BMC network interface by placing it on a private network or behind a firewall to prevent unauthorized access.
  • Implement firewall rules that allow only trusted management hosts to communicate with the BMC, ensuring that it is unreachable from external or untrusted networks.

Generated by OpenCVE AI on November 8, 2026 at 21:21 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories yet.

History

Sun, 08 Nov 2026 19:30:00 +0000

Type Values Removed Values Added
Description IBM Power Systems Firmware FW1060.00 through FW1060.81, OP940.00 through OP940.A2, OP910.00 through OP910.95, and OP940.00 through OP940.82 could allow a remote attacker to cause a denial of service due to improper validation of input length.
Title This Power System update is being released to address
First Time appeared Ibm
Ibm openbmc
Ibm power Hardware Management Console
Weaknesses CWE-617
CPEs cpe:2.3:a:ibm:openbmc:fw1060.00.0:*:*:*:*:*:*:*
cpe:2.3:a:ibm:openbmc:fw1060.00:*:*:*:*:*:*:*
cpe:2.3:a:ibm:openbmc:fw1060.81.0:*:*:*:*:*:*:*
cpe:2.3:a:ibm:openbmc:fw1060.81:*:*:*:*:*:*:*
cpe:2.3:a:ibm:openbmc:op910.00.0:*:*:*:*:*:*:*
cpe:2.3:a:ibm:openbmc:op910.00:*:*:*:*:*:*:*
cpe:2.3:a:ibm:openbmc:op910.95.0:*:*:*:*:*:*:*
cpe:2.3:a:ibm:openbmc:op910.95:*:*:*:*:*:*:*
cpe:2.3:a:ibm:openbmc:op940.00.0:*:*:*:*:*:*:*
cpe:2.3:a:ibm:openbmc:op940.00:*:*:*:*:*:*:*
cpe:2.3:a:ibm:openbmc:op940.a2.0:*:*:*:*:*:*:*
cpe:2.3:a:ibm:openbmc:op940.a2:*:*:*:*:*:*:*
cpe:2.3:a:ibm:power_hardware_management_console:op940.00.0:*:*:*:*:*:*:*
cpe:2.3:a:ibm:power_hardware_management_console:op940.00:*:*:*:*:*:*:*
cpe:2.3:a:ibm:power_hardware_management_console:op940.82.0:*:*:*:*:*:*:*
cpe:2.3:a:ibm:power_hardware_management_console:op940.82:*:*:*:*:*:*:*
Vendors & Products Ibm
Ibm openbmc
Ibm power Hardware Management Console
References
Metrics cvssV3_1

{'score': 6.5, 'vector': 'CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H'}


Subscriptions

Ibm Openbmc Power Hardware Management Console
cve-icon MITRE

Status: PUBLISHED

Assigner: ibm

Published:

Updated: 2026-11-08T19:15:50.339Z

Reserved: 2026-07-25T06:12:30.417Z

Link: CVE-2026-17427

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Awaiting Analysis

Published: 2026-11-08T20:17:24.663

Modified: 2026-11-08T20:17:24.790

Link: CVE-2026-17427

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

Updated: 2026-11-08T21:30:17Z

Weaknesses