Description
Default factory credentials with administrative access are enabled and persist even after configuring other administrator accounts.
Published: 2026-10-09
Score: 9.2 Critical
EPSS: < 1% Very Low
KEV: No
Impact: Unauthorized Administrative Access
Action: Immediate Patch
AI Analysis

Impact

The vulnerability lies in hard‑coded factory credentials that remain enabled for the N‑Tron 700 Series even after new administrator accounts are configured. Because these credentials provide full administrative rights, an attacker who can reach the device’s network can gain privileged access without needing any additional credentials. This extends to potential execution of arbitrary commands, configuration changes, and any data that can be read or altered by an admin user.

Affected Systems

Red Lion Controls N‑Tron 700 Series units running firmware versions older than 3.11.1 are affected. The advisory recommends upgrading to firmware 3.11.1 or later, disabling the SNMP communities, or disabling the web GUI to mitigate the issue.

Risk and Exploitability

The CVSS score is 9.2, indicating a high severity vulnerability. The EPSS score is not available, so the likelihood of exploitation cannot be quantified but the attack vector is likely network‑based, inferred from the nature of the credentials. The vulnerability is not listed in CISA KEV, but the high CVSS and presence of enduring factory credentials make it attractive for attackers with network access.

Generated by OpenCVE AI on October 9, 2026 at 15:27 UTC.

Remediation

Vendor Solution

Red Lion controls recommends the following upgrades for the N-Tron 700 Series: * Upgrade to firmware version 3.11.1 or greater * Configure or disable the SNMP communities * Disable access to the web GUI The upgrade procedure document can be viewed here https://www.hms-networks.com/ . The advisory issued by HMS Networks regarding these vulnerabilities can be viewed here https://www.hms-networks.com/cybersecurity .


OpenCVE Recommended Actions

  • Upgrade the device firmware to version 3.11.1 or later as published by Red Lion Controls.
  • Configure or disable SNMP community strings to prevent unauthorized SNMP access.
  • Disable or restrict access to the web GUI on the device to limit web‑based login attempts.

Generated by OpenCVE AI on October 9, 2026 at 15:27 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories yet.

History

Mon, 12 Oct 2026 23:30:00 +0000

Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}


Sun, 11 Oct 2026 12:45:00 +0000

Type Values Removed Values Added
First Time appeared Red Lion Controls
Red Lion Controls 700 Series
Vendors & Products Red Lion Controls
Red Lion Controls 700 Series

Fri, 09 Oct 2026 14:45:00 +0000


Fri, 09 Oct 2026 14:30:00 +0000

Type Values Removed Values Added
Description Default factory credentials with administrative access are enabled and persist even after configuring other administrator accounts.
Title Red Lion Controls N-Tron 700 Series Use of Hard-Coded Credentials
Weaknesses CWE-798
References
Metrics cvssV3_1

{'score': 6, 'vector': 'CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N'}

cvssV4_0

{'score': 9.2, 'vector': 'CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N'}


Subscriptions

Red Lion Controls 700 Series
cve-icon MITRE

Status: PUBLISHED

Assigner: icscert

Published:

Updated: 2026-10-12T22:54:01.723Z

Reserved: 2026-04-08T19:28:49.388Z

Link: CVE-2026-32645

cve-icon Vulnrichment

Updated: 2026-10-12T22:52:54.131Z

cve-icon NVD

Status : Awaiting Analysis

Published: 2026-10-09T15:17:14.017

Modified: 2026-10-12T23:17:37.503

Link: CVE-2026-32645

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

Updated: 2026-10-11T12:26:46Z

Weaknesses
  • CWE-798

    Use of Hard-coded Credentials