CVE-2026-51704

Published Aug 31, 2026 CVSS 3.1 · 4.3 Medium EPSS < 1% KEV · Not listed
Description
Incorrect access control in the setWiFiMeshConfig function of TOTOLINK T6 4.1.5cu.748_B20211015 allows unauthenticated attackers to alter mesh configurations via sending a crafted POST request to /cgi-bin/cstecgi.cgi.

Analysis

AI-generated

Technical impact

The vulnerability lies in the setWiFiMeshConfig function of the TOTOLINK T6. An attacker can provide a crafted POST request to the /cgi-bin/cstecgi.cgi endpoint without authentication, allowing them to alter router mesh settings. This change in configuration can disrupt network connectivity and potentially expose or isolate network segments. The flaw is a classic access‑control issue that defeats the device’s authorization mechanisms.

Affected Systems

TOTOLINK T6 firmware 4.1.5cu.748_B20211015 is affected. No other versions are listed in the CVE data.

Risk and Exploitability

The attack vector requires network access to the device and does not require prior authentication. An attacker can simply send a POST request, so the exploitation is straightforward. The CVSS score of 4.3, alongside an EPSS score of < 1%, indicates moderate severity and very low but non‑zero exploitation probability. The vulnerability is not currently listed in the CISA KEV catalog.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Apply a firmware update that resolves the access‑control flaw.
  • If no update is available, isolate the device from untrusted networks or block HTTP POST requests to /cgi-bin/cstecgi.cgi via a firewall.
  • Monitor the router’s configuration for unexpected changes and audit logs for unauthorized POST activity.

Generated by OpenCVE AI on September 2, 2026 at 04:46 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Title Improper Access Control in setWiFiMeshConfig Allows Unauthenticated Mesh Config Changes
Type Values Removed Values Added
Metrics cvssV3_1

{'score': 4.3, 'vector': 'CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N'}

ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
Title Improper Access Control in setWiFiMeshConfig Allows Unauthenticated Mesh Config Changes
Weaknesses CWE-284
Type Values Removed Values Added
First Time appeared Totolink
Totolink t6
Vendors & Products Totolink
Totolink t6
Type Values Removed Values Added
Description Incorrect access control in the setWiFiMeshConfig function of TOTOLINK T6 4.1.5cu.748_B20211015 allows unauthenticated attackers to alter mesh configurations via sending a crafted POST request to /cgi-bin/cstecgi.cgi.
References
Weaknesses

Sources

Status
PUBLISHED
Assigner
mitre
Published
Updated
Sep 1, 2026, 4:51 PM
Reserved
Jun 8, 2026, 12:00 AM
Status
Deferred
Published
Aug 31, 2026, 4:18 PM
Modified
Sep 1, 2026, 5:17 PM