CVE-2026-78557

Unsanitized Data in Industrial Edge App Publisher Enables Remote Code Execution

Published Oct 13, 2026 CVSS 4.0 · 7.7 High EPSS < 1% KEV · Not listed
Description
A vulnerability has been identified in Industrial Edge App Publisher (All versions < V1.27.9). The application fails to properly sanitize or escape data received from the backend before rendering it in the user interface. Because the front end is integrated with Node.js, this vulnerability allows for the execution of arbitrary JavaScript, which can be leveraged to achieve remote code execution (RCE) on the victim's machine

Analysis

AI-generated

Technical impact

The vulnerability resides in Industrial Edge App Publisher versions older than 1.27.9, where data received from the backend is rendered in the user interface without proper sanitization or escaping. The front end is built with Node.js, enabling the injection of arbitrary JavaScript that executes in the victim’s browser context. The ability to execute arbitrary code can lead to full control over the victim’s machine and compromise confidentiality, integrity, and availability of the managed edge device.

Affected Systems

Siemens Industrial Edge App Publisher is affected. All exposed instances running any version prior to 1.27.9 are vulnerable. The attack surface includes any system that provides data to the front‑end UI of the application.

Risk and Exploitability

With a CVSS score of 7.7, the vulnerability presents moderate to high severity. The EPSS score is not available, so the likelihood of exploitation is unknown, but the absence of a KEV listing suggests no widespread exploitation yet. The integrated Node.js runtime and lack of output encoding provide a clear path for an attacker to craft malicious payloads, making exploitation feasible if an attacker can influence backend responses or inject content.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Upgrade Industrial Edge App Publisher to version 1.27.9 or later
  • If upgrade is impossible, configure the front end to strictly filter or encode all data received from the backend before rendering
  • Deploy a web application firewall that blocks known malicious script patterns in incoming responses

Generated by OpenCVE AI on October 13, 2026 at 10:43 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
First Time appeared Siemens
Siemens industrial Edge App Publisher
Vendors & Products Siemens
Siemens industrial Edge App Publisher
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
Title Unsanitized Data in Industrial Edge App Publisher Enables Remote Code Execution
Type Values Removed Values Added
Description A vulnerability has been identified in Industrial Edge App Publisher (All versions < V1.27.9). The application fails to properly sanitize or escape data received from the backend before rendering it in the user interface. Because the front end is integrated with Node.js, this vulnerability allows for the execution of arbitrary JavaScript, which can be leveraged to achieve remote code execution (RCE) on the victim's machine
Weaknesses CWE-79
References
Metrics cvssV3_1

{'score': 8.3, 'vector': 'CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H'}

cvssV4_0

{'score': 7.7, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N'}

Weaknesses
  • CWE-79